EPA monitoring tested this supplier for 109 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
22
detected
4,461
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
6
violations on file
1
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2025-02-03
MR Monitoring Resolved 2023-12-02
MR Monitoring Resolved 2023-12-02
MR Monitoring Resolved 2023-12-02
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2014-12-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
482.8 µg/L 37%
of the EPA limit 1300 µg/L
worst single sample: 560 µg/L
37/43 SYR4 2014–2017
Nitrate
20 µg/L 0.2%
of the EPA limit 10000 µg/L
16/26 SYR4 2012–2019
Dibromochloromethane
8.49 µg/L
No EPA limit set
worst single sample: 10.8 µg/L
12/23 SYR4 2014–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
11/11 LCR 2023
Bromoform
4.25 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
10/23 SYR4 2014–2019
Bromodichloromethane
13.33 µg/L
No EPA limit set
worst single sample: 15.4 µg/L
7/23 SYR4 2014–2019
TTHM
60.7 µg/L 76%
of the EPA limit 80 µg/L
worst single sample: 66.4 µg/L
7/12 SYR4 2014–2019
Lead
2.975 µg/L 20%
of the EPA limit 15 µg/L
worst single sample: 3.3 µg/L
6/43 SYR4 2014–2017
Chloroform
44.1 µg/L
No EPA limit set
worst single sample: 48.9 µg/L
5/23 SYR4 2014–2019
Dichloroacetic Acid
3.54 µg/L
No EPA limit set
worst single sample: 3.7 µg/L
5/12 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
5.02 µg/L 8.4%
of the EPA limit 60 µg/L
worst single sample: 5.3 µg/L
5/12 SYR4 2014–2019
Barium
255.6 µg/L 13%
of the EPA limit 2000 µg/L
worst single sample: 258 µg/L
4/4 SYR4 2014–2019
Fluoride
498.5 µg/L 12%
of the EPA limit 4000 µg/L
worst single sample: 500 µg/L
4/4 SYR4 2014–2019
Gross Alpha, Excl. Radon And U
6.11 pCi/L 41%
of the EPA limit 15 pCi/L
worst single sample: 6.3 pCi/L
3/3 SYR4 2016–2019
Nitrate-Nitrite
10 µg/L 0.1%
of the EPA limit 10000 µg/L
3/4 SYR4 2012–2015
Combined Radium (-226 And -228)
2.5145 pCi/L 50%
of the EPA limit 5 pCi/L
worst single sample: 2.59 pCi/L
2/3 SYR4 2016–2019
Di(2-ethylhexyl) Phthalate
1.656 µg/L 28%
of the EPA limit 6 µg/L
worst single sample: 1.7 µg/L
2/10 SYR4 2014–2019
Dibromoacetic Acid
1.475 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
2/12 SYR4 2014–2019
Gross Beta Particle Activity
7.695 pCi/L
No EPA limit set
worst single sample: 7.8 pCi/L
2/3 SYR4 2016–2019
Lithium
35.6 µg/L
No EPA limit set
2/2 UCMR-5 2025
Trichloroacetic Acid
1.6 µg/L
No EPA limit set
1/12 SYR4 2014–2019
Xylenes, Total
0.6000 µg/L 0%
of the EPA limit 10000 µg/L
1/11 SYR4 2015–2019
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
COLEMAN, GREG
Phone
713-860-6400

Frequently asked questions about Harris County Mud 365

Is Harris County Mud 365 tap water safe to drink?

EPA monitoring detected 22 contaminants in Harris County Mud 365's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Harris County Mud 365's water?

EPA monitoring detected Copper, Nitrate, Dibromochloromethane, Lead, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Harris County Mud 365 serve?

Harris County Mud 365 reports serving 4,461 people in Texas, per its EPA record.

Has Harris County Mud 365 had any water quality violations?

The EPA has 6 violations on file for Harris County Mud 365, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.