← Texas

Tap water quality report

Harris County Mud 186

EPA monitoring tested this supplier for 109 contaminants and detected 29. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
29
detected
4,005
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2025-07-02
RPT Monitoring Resolved 2025-07-02
Other Monitoring Resolved 2011-03-12
Other Monitoring Resolved 2011-03-12
MR Monitoring Resolved 2010-11-01 → 2010-11-30
MR Monitoring Resolved 2010-11-01 → 2010-11-30
MR Monitoring Resolved 2010-11-01 → 2010-11-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0073 µg/L 2/4 2023
PFBS 0.0032 µg/L 2/4 2023
Pfhxa 0.0058 µg/L 2/4 2023
Pfpea 0.0065 µg/L 2/4 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
13 µg/L
No EPA limit set
67/67 SYR4 2012–2019
Chloroform
47.4 µg/L
No EPA limit set
67/67 SYR4 2012–2019
Dibromochloromethane
6.6 µg/L
No EPA limit set
64/67 SYR4 2012–2019
Copper
688 µg/L 53%
of the EPA limit 1300 µg/L
63/65 SYR4 2012–2018
Dichloroacetic Acid
50 µg/L
No EPA limit set
62/62 SYR4 2012–2019
TTHM
56.5 µg/L 71%
of the EPA limit 80 µg/L
62/62 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
73.7 µg/L 123%
of the EPA limit, in the worst sample — 60 µg/L
62/62 SYR4 2012–2019
Trichloroacetic Acid
18.3 µg/L
No EPA limit set
61/62 SYR4 2012–2019
Dibromoacetic Acid
5.4 µg/L
No EPA limit set
47/62 SYR4 2012–2019
Lead
80 µg/L 533%
of the EPA limit, in the worst sample — 15 µg/L
19/65 SYR4 2012–2018
Nitrate
780 µg/L 7.8%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0018 mg/L 12%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Bromoform
1.5 µg/L
No EPA limit set
8/67 SYR4 2012–2019
Atrazine
0.2800 µg/L 9.3%
of the EPA limit 3 µg/L
6/8 SYR4 2012–2019
Simazine
0.1500 µg/L 3.8%
of the EPA limit 4 µg/L
6/8 SYR4 2012–2019
Monochloroacetic Acid
5.4 µg/L
No EPA limit set
4/62 SYR4 2012–2019
Nitrate-Nitrite
650 µg/L 6.5%
of the EPA limit 10000 µg/L
3/3 SYR4 2012–2015
Barium
61.5 µg/L 3.1%
of the EPA limit 2000 µg/L
2/2 SYR4 2016–2019
Fluoride
450 µg/L 11%
of the EPA limit 4000 µg/L
2/2 SYR4 2014–2017
Lithium
20.9 µg/L
No EPA limit set
2/4 UCMR-5 2023
Cyanide
120 µg/L 60%
of the EPA limit 200 µg/L
1/2 SYR4 2014–2017
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2015
Combined Uranium
1.1 µg/L 3.7%
of the EPA limit 30 µg/L
1/1 SYR4 2015
Di(2-ethylhexyl) Phthalate
0.6100 µg/L 10%
of the EPA limit 6 µg/L
1/8 SYR4 2012–2019
Gross Beta Particle Activity
5.2 pCi/L
No EPA limit set
1/1 SYR4 2015
80 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ARMSTRONG, ANDY
Phone
713-651-5401
Email
kaitlyn.malek@nortonrosefulbright.com

Frequently asked questions about Harris County Mud 186

Is Harris County Mud 186 tap water safe to drink?

EPA monitoring detected 29 contaminants in Harris County Mud 186's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Harris County Mud 186's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Copper, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Harris County Mud 186 serve?

Harris County Mud 186 reports serving 4,005 people in Texas, per its EPA record.

Has Harris County Mud 186 had any water quality violations?

The EPA has 7 violations on file for Harris County Mud 186, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.