← Texas

Tap water quality report

Northwest Harris County Mud 10

EPA monitoring tested this supplier for 109 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
17
detected
7,671
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
22
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2014-12-30
Other Monitoring Resolved 2003-08-01
Other Monitoring Resolved 2003-07-01
Other Monitoring Resolved 2003-06-01
Other Monitoring Resolved 2003-05-01
MR Monitoring Resolved 2003-04-01 → 2003-04-30
MR Monitoring Resolved 2003-04-01 → 2003-04-30
MR Monitoring Resolved 2003-04-01 → 2003-04-30
MR Monitoring Resolved 2003-04-01 → 2003-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
275.8 µg/L 21%
of the EPA limit 1300 µg/L
worst single sample: 549 µg/L
35/46 SYR4 2013–2017
Nitrate
164.5 µg/L 1.6%
of the EPA limit 10000 µg/L
worst single sample: 170 µg/L
32/46 SYR4 2012–2019
Lead
0.00060 mg/L 4%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Barium
293.4 µg/L 15%
of the EPA limit 2000 µg/L
worst single sample: 294 µg/L
7/7 SYR4 2013–2019
Fluoride
757 µg/L 19%
of the EPA limit 4000 µg/L
worst single sample: 760 µg/L
7/7 SYR4 2013–2019
Lead
35.26 µg/L 235%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 49 µg/L
7/46 SYR4 2013–2017
Lithium
42.8 µg/L
No EPA limit set
6/6 UCMR-5 2025
Nitrate-Nitrite
82 µg/L 0.8%
of the EPA limit 10000 µg/L
worst single sample: 100 µg/L
5/5 SYR4 2012–2015
Arsenic
5.245 µg/L 52%
of the EPA limit 10 µg/L
worst single sample: 5.5 µg/L
4/7 SYR4 2013–2019
Dibromochloromethane
1.355 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
4/21 SYR4 2013–2019
Gross Beta Particle Activity
5.425 pCi/L
No EPA limit set
worst single sample: 5.5 pCi/L
4/4 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
8.48 pCi/L 57%
of the EPA limit 15 pCi/L
worst single sample: 8.9 pCi/L
3/4 SYR4 2013–2019
Combined Radium (-226 And -228)
1.0045 pCi/L 20%
of the EPA limit 5 pCi/L
worst single sample: 1.02 pCi/L
2/3 SYR4 2013–2019
Bromodichloromethane
0.7000 µg/L
No EPA limit set
1/21 SYR4 2013–2019
Bromoform
0.9000 µg/L
No EPA limit set
1/21 SYR4 2013–2019
Selenium
3 µg/L 6%
of the EPA limit 50 µg/L
1/7 SYR4 2013–2019
TTHM
1 µg/L 1.3%
of the EPA limit 80 µg/L
1/7 SYR4 2013–2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
YHARTE, WENSELADO
Phone
713-652-6500

Frequently asked questions about Northwest Harris County Mud 10

Is Northwest Harris County Mud 10 tap water safe to drink?

EPA monitoring detected 17 contaminants in Northwest Harris County Mud 10's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Northwest Harris County Mud 10's water?

EPA monitoring detected Copper, Nitrate, Lead, Barium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Northwest Harris County Mud 10 serve?

Northwest Harris County Mud 10 reports serving 7,671 people in Texas, per its EPA record.

Has Northwest Harris County Mud 10 had any water quality violations?

The EPA has 22 violations on file for Northwest Harris County Mud 10, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.