← Texas

Tap water quality report

Brittmoore Utility

EPA monitoring tested this supplier for 108 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
14
detected
3,732
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2009-03-01 → 2009-03-31
MCL Health-based Resolved 2009-03-01 → 2009-03-31
MCL Health-based Resolved 2009-03-01 → 2009-03-31
MCL Health-based Resolved 2009-03-01 → 2009-03-31
MR Monitoring Archived 1992-11-01 → 1992-11-30
MR Monitoring Archived 1991-08-01 → 1991-08-31
MR Monitoring Archived 1991-03-01 → 1991-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
640 µg/L 6.4%
of the EPA limit 10000 µg/L
26/42 SYR4 2012–2019
Copper
228 µg/L 18%
of the EPA limit 1300 µg/L
19/23 SYR4 2014–2017
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
10/10 LCR 2023
Lead
23.8 µg/L 159%
of the EPA limit, in the worst sample — 15 µg/L
8/23 SYR4 2014–2017
Nitrate-Nitrite
650 µg/L 6.5%
of the EPA limit 10000 µg/L
7/10 SYR4 2012–2015
Barium
280 µg/L 14%
of the EPA limit 2000 µg/L
4/4 SYR4 2014–2018
Fluoride
190 µg/L 4.8%
of the EPA limit 4000 µg/L
4/4 SYR4 2014–2017
Lithium
19.5 µg/L
No EPA limit set
4/4 UCMR-5 2023
Arsenic
5.3 µg/L 53%
of the EPA limit 10 µg/L
3/4 SYR4 2014–2018
Combined Radium (-226 And -228)
2.47 pCi/L 49%
of the EPA limit 5 pCi/L
2/3 SYR4 2012–2018
Combined Uranium
1.8 µg/L 6%
of the EPA limit 30 µg/L
2/2 SYR4 2017–2018
Gross Alpha, Excl. Radon And U
11 pCi/L 73%
of the EPA limit 15 pCi/L
2/2 SYR4 2017–2018
Nitrite
110 µg/L 11%
of the EPA limit 1000 µg/L
2/10 SYR4 2012–2015
Selenium
7.2 µg/L 14%
of the EPA limit 50 µg/L
1/4 SYR4 2014–2018
94 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FOLTZ, SCOT, W
Phone
512-990-4400
Email
swfoltz@aquaamerica.com

Frequently asked questions about Brittmoore Utility

Is Brittmoore Utility tap water safe to drink?

EPA monitoring detected 14 contaminants in Brittmoore Utility's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Brittmoore Utility's water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Brittmoore Utility serve?

Brittmoore Utility reports serving 3,732 people in Texas, per its EPA record.

Has Brittmoore Utility had any water quality violations?

The EPA has 7 violations on file for Brittmoore Utility, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.