← Texas

Tap water quality report

Westador Mud

EPA monitoring tested this supplier for 108 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
22
detected
5,337
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
2
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2005-07-01
MR Monitoring Resolved 1992-07-01 → 1993-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
287 µg/L 22%
of the EPA limit 1300 µg/L
150/165 SYR4 2013–2019
Lead
91.1 µg/L 607%
of the EPA limit, in the worst sample — 15 µg/L
110/165 SYR4 2013–2019
Chloroform
26.2 µg/L
No EPA limit set
63/70 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
23.7 µg/L 39%
of the EPA limit 60 µg/L
59/62 SYR4 2012–2019
Dichloroacetic Acid
21.3 µg/L
No EPA limit set
58/62 SYR4 2012–2019
TTHM
28.8 µg/L 36%
of the EPA limit 80 µg/L
58/62 SYR4 2012–2019
Bromodichloromethane
5 µg/L
No EPA limit set
53/70 SYR4 2012–2019
Trichloroacetic Acid
3.5 µg/L
No EPA limit set
50/62 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Dibromoacetic Acid
2.1 µg/L
No EPA limit set
19/62 SYR4 2012–2019
Dibromochloromethane
3.8 µg/L
No EPA limit set
14/70 SYR4 2012–2019
Monochloroacetic Acid
3.6 µg/L
No EPA limit set
14/62 SYR4 2012–2019
Nitrate
670 µg/L 6.7%
of the EPA limit 10000 µg/L
14/16 SYR4 2012–2019
Bromoform
2.2 µg/L
No EPA limit set
9/70 SYR4 2012–2019
Lithium
33.6 µg/L
No EPA limit set
4/4 UCMR-5 2023
Nitrate-Nitrite
690 µg/L 6.9%
of the EPA limit 10000 µg/L
3/3 SYR4 2012–2015
Barium
209 µg/L 10%
of the EPA limit 2000 µg/L
2/2 SYR4 2014–2017
Fluoride
550 µg/L 14%
of the EPA limit 4000 µg/L
2/2 SYR4 2014–2017
Nitrite
20 µg/L 2%
of the EPA limit 1000 µg/L
2/3 SYR4 2012–2015
Atrazine
0.1700 µg/L 5.7%
of the EPA limit 3 µg/L
1/3 SYR4 2012–2018
Cyanide
60 µg/L 30%
of the EPA limit 200 µg/L
1/2 SYR4 2014–2017
Gross Beta Particle Activity
4 pCi/L
No EPA limit set
1/1 SYR4 2016
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MURPHY, RICHARD, C
Phone
713-623-4531

Frequently asked questions about Westador Mud

Is Westador Mud tap water safe to drink?

EPA monitoring detected 22 contaminants in Westador Mud's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Westador Mud's water?

EPA monitoring detected Copper, Lead, Chloroform, Total Haloacetic Acids (HAA5), Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Westador Mud serve?

Westador Mud reports serving 5,337 people in Texas, per its EPA record.

Has Westador Mud had any water quality violations?

The EPA has 2 violations on file for Westador Mud, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.