Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2020-10-01 → 2020-12-31 |
| MR | Monitoring | Resolved | 2020-10-01 → 2020-12-31 |
| MR | Monitoring | Resolved | 2020-10-01 → 2020-12-31 |
| MR | Monitoring | Resolved | 2020-10-01 → 2020-12-31 |
| MR | Monitoring | Archived | 2018-01-01 → 2020-12-31 |
| MR | Monitoring | Resolved | 2016-12-30 |
| MR | Monitoring | Resolved | 2016-12-30 |
| MR | Monitoring | Resolved | 2016-04-01 → 2016-06-30 |
| MR | Monitoring | Resolved | 2016-04-01 → 2016-06-30 |
| MR | Monitoring | Resolved | 2016-04-01 → 2016-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 434.85 µg/L 33% of the EPA limit 1300 µg/L
worst single sample: 437 µg/L | 22/24 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2.1 µg/L No EPA limit set
worst single sample: 2.2 µg/L | 11/25 | SYR4 | 2013–2019 |
| TTHM | 4.325 µg/L 5.4% of the EPA limit 80 µg/L
worst single sample: 5.2 µg/L | 8/13 | SYR4 | 2013–2019 |
| Bromoform | 1.67 µg/L No EPA limit set
worst single sample: 1.7 µg/L | 7/25 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 7/7 | LCR | 2025 |
| Barium | 154.75 µg/L 7.7% of the EPA limit 2000 µg/L
worst single sample: 157 µg/L | 6/6 | SYR4 | 2012–2019 |
| Fluoride | 757.5 µg/L 19% of the EPA limit 4000 µg/L
worst single sample: 760 µg/L | 6/6 | SYR4 | 2012–2019 |
| Nitrate | 10 µg/L 0.1% of the EPA limit 10000 µg/L | 4/30 | SYR4 | 2012–2019 |
| Arsenic | 6.43 µg/L 64% of the EPA limit 10 µg/L
worst single sample: 6.5 µg/L | 3/6 | SYR4 | 2012–2019 |
| Lead | 13.868 µg/L 92% of the EPA limit 15 µg/L
worst single sample: 15 µg/L | 3/24 | SYR4 | 2012–2019 |
| Bromodichloromethane | 1.29 µg/L No EPA limit set
worst single sample: 1.3 µg/L | 2/25 | SYR4 | 2013–2019 |
| Chloroform | 1 µg/L No EPA limit set | 1/25 | SYR4 | 2013–2019 |
| Di(2-ethylhexyl) Phthalate | 0.6500 µg/L 11% of the EPA limit 6 µg/L | 1/9 | SYR4 | 2013–2019 |
| Selenium | 4.1 µg/L 8.2% of the EPA limit 50 µg/L | 1/6 | SYR4 | 2012–2019 |
64 contaminants tested, none detected
Utility contact
Frequently asked questions about Harris County Wcid 70
Is Harris County Wcid 70 tap water safe to drink?
EPA monitoring detected 14 contaminants in Harris County Wcid 70's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Harris County Wcid 70's water?
EPA monitoring detected Copper, Dibromochloromethane, TTHM, Bromoform, Lead, and others. The full list with the level and data source for each is above.
How many people does Harris County Wcid 70 serve?
Harris County Wcid 70 reports serving 2,112 people in Texas, per its EPA record.
Has Harris County Wcid 70 had any water quality violations?
The EPA has 23 violations on file for Harris County Wcid 70, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.