← Texas

Tap water quality report

City of Schertz

EPA monitoring tested this supplier for 108 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
19
detected
41,948
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Guadalupe

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
20
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2025-07-01 → 2025-12-31
MR Monitoring Archived 2025-07-01 → 2025-12-31
MR Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2025-01-01 → 2025-06-30
MR Monitoring Resolved 2025-01-01 → 2025-06-30
MR Monitoring Resolved 2025-01-01 → 2025-06-30
Other Monitoring Resolved 2022-07-01
Other Monitoring Resolved 2022-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
12.1 µg/L
No EPA limit set
125/127 SYR4 2012–2019
Dibromochloromethane
10.7 µg/L
No EPA limit set
125/127 SYR4 2012–2019
TTHM
30.8 µg/L 39%
of the EPA limit 80 µg/L
123/125 SYR4 2012–2019
Bromoform
9.2 µg/L
No EPA limit set
118/127 SYR4 2012–2019
Copper
170 µg/L 13%
of the EPA limit 1300 µg/L
84/92 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
11.4 µg/L 19%
of the EPA limit 60 µg/L
84/124 SYR4 2012–2019
Dibromoacetic Acid
4.5 µg/L
No EPA limit set
76/124 SYR4 2012–2019
Chloroform
4.4 µg/L
No EPA limit set
43/127 SYR4 2012–2019
Dichloroacetic Acid
3.1 µg/L
No EPA limit set
36/124 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2026
Nitrate
1780 µg/L 18%
of the EPA limit 10000 µg/L
14/32 SYR4 2012–2019
Lead
6.6 µg/L 44%
of the EPA limit 15 µg/L
9/92 SYR4 2013–2019
Lithium
17.6 µg/L
No EPA limit set
6/6 UCMR-5 2024
Monochloroacetic Acid
10.4 µg/L
No EPA limit set
5/124 SYR4 2012–2019
Trichloroacetic Acid
1.5 µg/L
No EPA limit set
4/124 SYR4 2012–2019
Nitrate-Nitrite
1780 µg/L 18%
of the EPA limit 10000 µg/L
3/7 SYR4 2012–2015
Barium
100 µg/L 5%
of the EPA limit 2000 µg/L
2/2 SYR4 2014–2017
Fluoride
140 µg/L 3.5%
of the EPA limit 4000 µg/L
2/2 SYR4 2014–2017
Gross Beta Particle Activity
6.7 pCi/L
No EPA limit set
2/2 SYR4 2012–2017
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RODRIGUEZ, RALPH
Phone
210-619-1812

Frequently asked questions about City of Schertz

Is City of Schertz tap water safe to drink?

EPA monitoring detected 19 contaminants in City of Schertz's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Schertz's water?

EPA monitoring detected Bromodichloromethane, Dibromochloromethane, TTHM, Bromoform, Copper, and others. The full list with the level and data source for each is above.

How many people does City of Schertz serve?

City of Schertz reports serving 41,948 people in Texas, per its EPA record.

Has City of Schertz had any water quality violations?

The EPA has 20 violations on file for City of Schertz, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.