← Texas

Tap water quality report

Gonzales County Wsc

EPA monitoring tested this supplier for 109 contaminants and detected 30. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
30
detected
10,350
people served
11
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Gonzales

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

11
health-based violations
155
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-12-01 → 2010-12-31
MCL Health-based Resolved 2010-12-01 → 2010-12-31
MCL Health-based Resolved 2010-12-01 → 2010-12-31
MCL Health-based Resolved 2005-11-01 → 2005-11-30
MCL Health-based Resolved 2005-11-01 → 2005-11-30
MCL Health-based Resolved 2005-11-01 → 2005-11-30
MCL Health-based Resolved 2005-11-01 → 2005-11-30
MCL Health-based Resolved 2005-09-01 → 2005-09-30
MCL Health-based Resolved 2005-09-01 → 2005-09-30
MCL Health-based Resolved 2005-09-01 → 2005-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfpea 0.0041 µg/L 2/16 2024
Pfba 0.0061 µg/L 1/16 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
360 µg/L 28%
of the EPA limit 1300 µg/L
56/69 SYR4 2012–2018
Dibromochloromethane
28 µg/L
No EPA limit set
56/87 SYR4 2012–2019
Nitrate
2040 µg/L 20%
of the EPA limit 10000 µg/L
54/138 SYR4 2012–2019
TTHM
239 µg/L 299%
of the EPA limit, in the worst sample — 80 µg/L
48/62 SYR4 2012–2019
Bromoform
5.6 µg/L
No EPA limit set
43/87 SYR4 2012–2019
Bromodichloromethane
42 µg/L
No EPA limit set
19/87 SYR4 2012–2019
Barium
283 µg/L 14%
of the EPA limit 2000 µg/L
18/18 SYR4 2012–2019
Dibromoacetic Acid
6.4 µg/L
No EPA limit set
15/62 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Total Haloacetic Acids (HAA5)
200 µg/L 333%
of the EPA limit, in the worst sample — 60 µg/L
15/62 SYR4 2012–2019
Lithium
50.7 µg/L
No EPA limit set
14/16 UCMR-5 2023
Chloroform
189 µg/L
No EPA limit set
12/87 SYR4 2012–2019
Lead
17 µg/L 113%
of the EPA limit, in the worst sample — 15 µg/L
12/69 SYR4 2012–2018
Fluoride
230 µg/L 5.8%
of the EPA limit 4000 µg/L
11/20 SYR4 2012–2019
Nitrate-Nitrite
1220 µg/L 12%
of the EPA limit 10000 µg/L
9/20 SYR4 2012–2015
Dichloroacetic Acid
116.4 µg/L
No EPA limit set
8/62 SYR4 2012–2019
Gross Beta Particle Activity
13.1 pCi/L
No EPA limit set
8/10 SYR4 2012–2018
Combined Radium (-226 And -228)
3.4 pCi/L 68%
of the EPA limit 5 pCi/L
6/6 SYR4 2012–2018
Trichloroacetic Acid
71.3 µg/L
No EPA limit set
6/62 SYR4 2012–2019
Xylenes, Total
1.01 µg/L 0%
of the EPA limit 10000 µg/L
3/25 SYR4 2012–2019
Cyanide
70 µg/L 35%
of the EPA limit 200 µg/L
2/15 SYR4 2014–2019
Gross Alpha, Excl. Radon And U
5.1 pCi/L 34%
of the EPA limit 15 pCi/L
2/7 SYR4 2015–2018
Monobromoacetic Acid
2.7 µg/L
No EPA limit set
2/62 SYR4 2012–2019
Monochloroacetic Acid
10.8 µg/L
No EPA limit set
2/62 SYR4 2012–2019
Arsenic
2.4 µg/L 24%
of the EPA limit 10 µg/L
1/18 SYR4 2012–2019
Atrazine
0.1400 µg/L 4.7%
of the EPA limit 3 µg/L
1/42 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.9300 µg/L 16%
of the EPA limit 6 µg/L
1/42 SYR4 2012–2019
Hexachlorocyclopentadiene
0.2300 µg/L 0.5%
of the EPA limit 50 µg/L
1/42 SYR4 2012–2019
79 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SAMPLE, BRIAN
Phone
830-672-6500
Email
gcwsc@gvec.net

Frequently asked questions about Gonzales County Wsc

Is Gonzales County Wsc tap water safe to drink?

EPA monitoring detected 30 contaminants in Gonzales County Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Gonzales County Wsc's water?

EPA monitoring detected Copper, Dibromochloromethane, Nitrate, TTHM, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Gonzales County Wsc serve?

Gonzales County Wsc reports serving 10,350 people in Texas, per its EPA record.

Has Gonzales County Wsc had any water quality violations?

The EPA has 155 violations on file for Gonzales County Wsc, of which 11 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.