EPA monitoring tested this supplier for 109 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
17
detected
4,260
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Fort Bend

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
10
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2015-11-01 → 2015-11-30
MR Monitoring Resolved 2015-11-01 → 2015-11-30
MR Monitoring Resolved 2015-11-01 → 2015-11-30
MR Monitoring Resolved 2015-11-01 → 2015-11-30
MR Monitoring Resolved 2015-11-01 → 2015-11-30
MR Monitoring Resolved 2015-10-01 → 2015-10-31
MR Monitoring Resolved 2015-10-01 → 2015-10-31
MR Monitoring Resolved 2015-10-01 → 2015-10-31
MR Monitoring Resolved 2015-10-01 → 2015-10-31
MR Monitoring Resolved 2015-10-01 → 2015-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
155 µg/L 12%
of the EPA limit 1300 µg/L
47/64 SYR4 2013–2019
Nitrate
90 µg/L 0.9%
of the EPA limit 10000 µg/L
30/32 SYR4 2012–2019
Lead
6.19 µg/L 41%
of the EPA limit 15 µg/L
16/64 SYR4 2013–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Nitrate-Nitrite
90 µg/L 0.9%
of the EPA limit 10000 µg/L
6/6 SYR4 2012–2015
Barium
180 µg/L 9%
of the EPA limit 2000 µg/L
4/4 SYR4 2014–2017
Fluoride
330 µg/L 8.3%
of the EPA limit 4000 µg/L
4/4 SYR4 2014–2017
Lithium
15.7 µg/L
No EPA limit set
4/4 UCMR-5 2024
Combined Radium (-226 And -228)
2.89 pCi/L 58%
of the EPA limit 5 pCi/L
3/3 SYR4 2014–2017
Combined Uranium
4.6 µg/L 15%
of the EPA limit 30 µg/L
3/3 SYR4 2014–2017
Gross Alpha, Excl. Radon And U
11 pCi/L 73%
of the EPA limit 15 pCi/L
3/3 SYR4 2014–2017
Xylenes, Total
2.9 µg/L 0%
of the EPA limit 10000 µg/L
3/13 SYR4 2012–2019
Arsenic
2.4 µg/L 24%
of the EPA limit 10 µg/L
2/4 SYR4 2014–2017
Dichloroacetic Acid
1.7 µg/L
No EPA limit set
1/8 SYR4 2013–2019
Ethylbenzene
0.5000 µg/L 0.1%
of the EPA limit 700 µg/L
1/13 SYR4 2012–2019
Gross Beta Particle Activity
5.1 pCi/L
No EPA limit set
1/3 SYR4 2014–2017
Total Haloacetic Acids (HAA5)
1.7 µg/L 2.8%
of the EPA limit 60 µg/L
1/8 SYR4 2013–2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDinosebEthylene DibromideEndrinHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RICCO, JODY
Phone
713-623-4531

Frequently asked questions about Plantation Mud

Is Plantation Mud tap water safe to drink?

EPA monitoring detected 17 contaminants in Plantation Mud's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Plantation Mud's water?

EPA monitoring detected Copper, Nitrate, Lead, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Plantation Mud serve?

Plantation Mud reports serving 4,260 people in Texas, per its EPA record.

Has Plantation Mud had any water quality violations?

The EPA has 10 violations on file for Plantation Mud, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.