Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Resolved | 2019-06-01 |
| Other | Monitoring | Resolved | 2019-06-01 |
| MON | Monitoring | Resolved | 2018-05-01 → 2018-05-31 |
| MON | Monitoring | Resolved | 2018-05-01 → 2018-05-31 |
| MON | Monitoring | Resolved | 2018-05-01 → 2018-05-31 |
| MON | Monitoring | Resolved | 2018-05-01 → 2018-05-31 |
| Other | Monitoring | Resolved | 2017-08-31 |
| Other | Monitoring | Resolved | 2017-08-31 |
| MR | Monitoring | Resolved | 2017-04-01 → 2017-06-30 |
| MR | Monitoring | Resolved | 2017-04-01 → 2017-06-30 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 773.9 µg/L 7.7% of the EPA limit 10000 µg/L
worst single sample: 829 µg/L | 40/40 | SYR4 | 2012–2019 |
| Copper | 124 µg/L 9.5% of the EPA limit 1300 µg/L
worst single sample: 170 µg/L | 33/33 | SYR4 | 2012–2019 |
| Bromoform | 3.8095 µg/L No EPA limit set
worst single sample: 4.96 µg/L | 14/22 | SYR4 | 2012–2019 |
| Dibromochloromethane | 10.785 µg/L No EPA limit set
worst single sample: 11.5 µg/L | 14/22 | SYR4 | 2012–2019 |
| TTHM | 39.1 µg/L 49% of the EPA limit 80 µg/L
worst single sample: 39.4 µg/L | 7/9 | SYR4 | 2013–2019 |
| Bromodichloromethane | 14.2 µg/L No EPA limit set | 5/22 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 23.32 µg/L 39% of the EPA limit 60 µg/L
worst single sample: 23.7 µg/L | 5/9 | SYR4 | 2013–2019 |
| Barium | 7.055 µg/L 0.4% of the EPA limit 2000 µg/L
worst single sample: 7.1 µg/L | 4/4 | SYR4 | 2012–2018 |
| Fluoride | 1791.5 µg/L 45% of the EPA limit 4000 µg/L
worst single sample: 1820 µg/L | 4/4 | SYR4 | 2012–2018 |
| Lead | 0.0011 mg/L 7.1% of the EPA limit 0.0150 mg/L | 4/4 | LCR | 2025 |
| Lithium | 47 µg/L No EPA limit set | 4/8 | UCMR-5 | 2025 |
| Chromium | 8.64 µg/L 8.6% of the EPA limit 100 µg/L
worst single sample: 8.8 µg/L | 3/4 | SYR4 | 2012–2018 |
| Dibromoacetic Acid | 6.05 µg/L No EPA limit set
worst single sample: 6.2 µg/L | 3/9 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 14.13 µg/L No EPA limit set
worst single sample: 14.4 µg/L | 3/9 | SYR4 | 2013–2019 |
| Chloroform | 12.354 µg/L No EPA limit set
worst single sample: 12.5 µg/L | 2/22 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 3.02 pCi/L 60% of the EPA limit 5 pCi/L
worst single sample: 3.1 pCi/L | 2/2 | SYR4 | 2012–2018 |
| Monochloroacetic Acid | 1.885 µg/L No EPA limit set
worst single sample: 1.9 µg/L | 2/9 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 56.21 µg/L 0.6% of the EPA limit 10000 µg/L
worst single sample: 56.3 µg/L | 2/2 | SYR4 | 2014–2019 |
| Trichloroacetic Acid | 3.535 µg/L No EPA limit set
worst single sample: 3.6 µg/L | 2/9 | SYR4 | 2013–2019 |
| Antimony, Total | 0.2620 µg/L 4.4% of the EPA limit 6 µg/L | 1/4 | SYR4 | 2012–2018 |
| Arsenic | 0.8970 µg/L 9% of the EPA limit 10 µg/L | 1/4 | SYR4 | 2012–2018 |
| Ethylbenzene | 0.6360 µg/L 0.1% of the EPA limit 700 µg/L | 1/13 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 3.2 pCi/L 21% of the EPA limit 15 pCi/L | 1/3 | SYR4 | 2015–2018 |
| Monobromoacetic Acid | 1 µg/L No EPA limit set | 1/9 | SYR4 | 2013–2019 |
| Selenium | 3.95 µg/L 7.9% of the EPA limit 50 µg/L | 1/4 | SYR4 | 2012–2018 |
| Thallium, Total | 0.0040 µg/L 0.2% of the EPA limit 2 µg/L | 1/4 | SYR4 | 2012–2018 |
| Xylenes, Total | 2.34 µg/L 0% of the EPA limit 10000 µg/L | 1/13 | SYR4 | 2012–2019 |
78 contaminants tested, none detected
Utility contact
Frequently asked questions about Frisco West Wcid
Is Frisco West Wcid tap water safe to drink?
EPA monitoring detected 31 contaminants in Frisco West Wcid's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Frisco West Wcid's water?
EPA monitoring detected Nitrate, Copper, Bromoform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.
How many people does Frisco West Wcid serve?
Frisco West Wcid reports serving 5,805 people in Texas, per its EPA record.
Has Frisco West Wcid had any water quality violations?
The EPA has 52 violations on file for Frisco West Wcid, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.