Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| MCL | Health-based | Resolved | 2012-09-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2012-09-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2012-09-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2012-09-01 → 2012-09-30 |
| RPT | Monitoring | Unaddressed | 2025-07-02 |
| Other | Monitoring | Resolved | 2025-05-15 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 149 µg/L 11% of the EPA limit 1300 µg/L
worst single sample: 170 µg/L | 23/29 | SYR4 | 2012–2017 |
| Nitrate | 22 µg/L 0.2% of the EPA limit 10000 µg/L | 8/16 | SYR4 | 2012–2019 |
| Bromoform | 13.3 µg/L No EPA limit set
worst single sample: 14.1 µg/L | 6/9 | SYR4 | 2012–2019 |
| Lead | 3.6 µg/L 24% of the EPA limit 15 µg/L
worst single sample: 4.1 µg/L | 6/29 | SYR4 | 2012–2017 |
| Dibromochloromethane | 1.876 µg/L No EPA limit set
worst single sample: 1.9 µg/L | 4/9 | SYR4 | 2012–2019 |
| Barium | 5.561 µg/L 0.3% of the EPA limit 2000 µg/L
worst single sample: 5.59 µg/L | 3/3 | SYR4 | 2012–2019 |
| Fluoride | 452.2 µg/L 11% of the EPA limit 4000 µg/L
worst single sample: 468 µg/L | 3/3 | SYR4 | 2013–2019 |
| TTHM | 15.44 µg/L 19% of the EPA limit 80 µg/L
worst single sample: 15.8 µg/L | 3/3 | SYR4 | 2013–2019 |
| Cyanide | 29.9175 µg/L 15% of the EPA limit 200 µg/L
worst single sample: 31.2 µg/L | 2/2 | SYR4 | 2014–2017 |
| Nitrate-Nitrite | 14.9 µg/L 0.1% of the EPA limit 10000 µg/L
worst single sample: 15 µg/L | 2/3 | SYR4 | 2012–2015 |
| Arsenic | 0.8150 µg/L 8.1% of the EPA limit 10 µg/L | 1/3 | SYR4 | 2012–2019 |
| Chromium | 2.9 µg/L 2.9% of the EPA limit 100 µg/L | 1/3 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.4 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
| Lead | 0.00055 mg/L 3.7% of the EPA limit 0.0150 mg/L | 1/1 | LCR | 2024 |
| Monochloroacetic Acid | 2.4 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
| Selenium | 1.49 µg/L 3% of the EPA limit 50 µg/L | 1/3 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 3.8 µg/L 6.3% of the EPA limit 60 µg/L | 1/3 | SYR4 | 2013–2019 |
61 contaminants tested, none detected
Utility contact
Frequently asked questions about Walnut Bend Isd
Is Walnut Bend Isd tap water safe to drink?
EPA monitoring detected 17 contaminants in Walnut Bend Isd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Walnut Bend Isd's water?
EPA monitoring detected Copper, Nitrate, Bromoform, Lead, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Walnut Bend Isd serve?
Walnut Bend Isd reports serving 162 people in Texas, per its EPA record.
Has Walnut Bend Isd had any water quality violations?
The EPA has 62 violations on file for Walnut Bend Isd, of which 8 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.