Tap water quality report

Woodbine Special Utility District

EPA monitoring tested this supplier for 109 contaminants and detected 28. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
28
detected
7,689
people served
5
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Cooke

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
10
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Archived 1991-03-01 → 1991-03-31
Other Monitoring Unaddressed 2025-07-01
Other Monitoring Unaddressed 2025-07-01
MR Monitoring Resolved 2024-12-30
MR Monitoring Resolved 2024-12-30
MR Monitoring Resolved 1992-07-01 → 1993-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
6:2 Fts 0.0062 µg/L 1/11 2023
Pfba 0.0053 µg/L 1/11 2023
Pfhxa 0.0041 µg/L 1/11 2023
Pfpea 0.0035 µg/L 1/11 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
73.1 µg/L 0.7%
of the EPA limit 10000 µg/L
worst single sample: 184 µg/L
130/146 SYR4 2012–2019
Copper
130 µg/L 10%
of the EPA limit 1300 µg/L
worst single sample: 240 µg/L
75/77 SYR4 2012–2019
Bromoform
13.9 µg/L
No EPA limit set
worst single sample: 21.4 µg/L
47/62 SYR4 2012–2019
Dibromochloromethane
2.15 µg/L
No EPA limit set
worst single sample: 2.23 µg/L
41/62 SYR4 2012–2019
Barium
65.25 µg/L 3.3%
of the EPA limit 2000 µg/L
worst single sample: 70 µg/L
26/26 SYR4 2012–2019
Fluoride
338 µg/L 8.5%
of the EPA limit 4000 µg/L
worst single sample: 361 µg/L
23/23 SYR4 2012–2019
Chromium
4.03 µg/L 4%
of the EPA limit 100 µg/L
worst single sample: 4.52 µg/L
21/26 SYR4 2012–2019
Lithium
28.3 µg/L
No EPA limit set
18/18 UCMR-5 2023
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
Bromodichloromethane
1.8505 µg/L
No EPA limit set
worst single sample: 2 µg/L
14/62 SYR4 2012–2019
Lead
2.91 µg/L 19%
of the EPA limit 15 µg/L
worst single sample: 3.3 µg/L
14/77 SYR4 2012–2019
TTHM
22.18 µg/L 28%
of the EPA limit 80 µg/L
worst single sample: 22.6 µg/L
8/11 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
7.925 µg/L 13%
of the EPA limit 60 µg/L
worst single sample: 8.1 µg/L
8/8 SYR4 2012–2019
Dibromoacetic Acid
2.91 µg/L
No EPA limit set
worst single sample: 3 µg/L
7/8 SYR4 2012–2019
Nitrate-Nitrite
33.5 µg/L 0.3%
of the EPA limit 10000 µg/L
worst single sample: 34 µg/L
6/13 SYR4 2012–2019
Monochloroacetic Acid
5.94 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
5/8 SYR4 2012–2019
Selenium
3.288 µg/L 6.6%
of the EPA limit 50 µg/L
worst single sample: 3.52 µg/L
3/26 SYR4 2012–2019
Arsenic
1.1584 µg/L 12%
of the EPA limit 10 µg/L
worst single sample: 1.18 µg/L
2/26 SYR4 2012–2019
Chloroform
1.0885 µg/L
No EPA limit set
worst single sample: 1.09 µg/L
2/62 SYR4 2012–2019
Combined Radium (-226 And -228)
2.6435 pCi/L 53%
of the EPA limit 5 pCi/L
worst single sample: 2.73 pCi/L
2/2 SYR4 2013–2019
Xylenes, Total
5.6655 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 5.93 µg/L
2/55 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.5000 µg/L 8.3%
of the EPA limit 6 µg/L
1/33 SYR4 2012–2019
Ethylbenzene
0.9000 µg/L 0.1%
of the EPA limit 700 µg/L
1/55 SYR4 2012–2019
Toluene
0.9600 µg/L 0.1%
of the EPA limit 1000 µg/L
1/55 SYR4 2012–2019
81 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDichloroacetic AcidDinosebEthylene DibromideEndrinGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DUGGER, VERNON
Phone
940-668-8337
Email
service@woodbinewater.com

Frequently asked questions about Woodbine Special Utility District

Is Woodbine Special Utility District tap water safe to drink?

EPA monitoring detected 28 contaminants in Woodbine Special Utility District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Woodbine Special Utility District's water?

EPA monitoring detected Nitrate, Copper, Bromoform, Dibromochloromethane, Barium, and others. The full list with the level and data source for each is above.

How many people does Woodbine Special Utility District serve?

Woodbine Special Utility District reports serving 7,689 people in Texas, per its EPA record.

Has Woodbine Special Utility District had any water quality violations?

The EPA has 10 violations on file for Woodbine Special Utility District, of which 5 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.