Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| MCL | Health-based | Resolved | 2019-07-01 → 2019-09-30 |
| MCL | Health-based | Resolved | 2019-07-01 → 2019-09-30 |
| MCL | Health-based | Resolved | 2019-07-01 → 2019-09-30 |
| MCL | Health-based | Resolved | 2019-07-01 → 2019-09-30 |
| MCL | Health-based | Archived | 1993-12-01 → 1993-12-31 |
| Other | Monitoring | Unaddressed | 2026-04-24 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfba | 0.0055 µg/L | 3/12 | 2025 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 206.5 µg/L 16% of the EPA limit 1300 µg/L
worst single sample: 380 µg/L | 90/90 | SYR4 | 2014–2018 |
| Lead | 2.36 µg/L 16% of the EPA limit 15 µg/L
worst single sample: 3.3 µg/L | 65/90 | SYR4 | 2014–2018 |
| Nitrate | 865.8 µg/L 8.7% of the EPA limit 10000 µg/L
worst single sample: 1020 µg/L | 62/64 | SYR4 | 2012–2019 |
| Dibromochloromethane | 23.58 µg/L No EPA limit set
worst single sample: 33.7 µg/L | 45/47 | SYR4 | 2012–2019 |
| Bromoform | 7.2905 µg/L No EPA limit set
worst single sample: 9.71 µg/L | 44/47 | SYR4 | 2012–2019 |
| Bromodichloromethane | 27.155 µg/L No EPA limit set
worst single sample: 39.7 µg/L | 40/47 | SYR4 | 2012–2019 |
| Chloroform | 24 µg/L No EPA limit set
worst single sample: 25.9 µg/L | 31/47 | SYR4 | 2012–2019 |
| TTHM | 80.57 µg/L 101% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 109 µg/L | 27/29 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 30.46 µg/L 51% of the EPA limit 60 µg/L
worst single sample: 34 µg/L | 25/27 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 7.46 µg/L No EPA limit set
worst single sample: 9.9 µg/L | 22/27 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 17.8 µg/L No EPA limit set
worst single sample: 17.9 µg/L | 21/27 | SYR4 | 2012–2019 |
| Lead | 0.0011 mg/L 7.1% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2025 |
| Monochloroacetic Acid | 4.35 µg/L No EPA limit set
worst single sample: 4.5 µg/L | 16/27 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 3.875 µg/L No EPA limit set
worst single sample: 4.1 µg/L | 16/27 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 2.25 µg/L No EPA limit set
worst single sample: 2.6 µg/L | 15/27 | SYR4 | 2012–2019 |
| Fluoride | 2156 µg/L 54% of the EPA limit 4000 µg/L
worst single sample: 2330 µg/L | 13/13 | SYR4 | 2012–2018 |
| Barium | 33.55 µg/L 1.7% of the EPA limit 2000 µg/L
worst single sample: 36 µg/L | 8/8 | SYR4 | 2015–2018 |
| Nitrate-Nitrite | 772.95 µg/L 7.7% of the EPA limit 10000 µg/L
worst single sample: 879 µg/L | 8/8 | SYR4 | 2014–2019 |
| Atrazine | 0.1000 µg/L 3.3% of the EPA limit 3 µg/L | 7/20 | SYR4 | 2012–2019 |
| Chromium | 2.95 µg/L 3% of the EPA limit 100 µg/L
worst single sample: 3 µg/L | 6/8 | SYR4 | 2015–2018 |
| Combined Radium (-226 And -228) | 2.025 pCi/L 41% of the EPA limit 5 pCi/L
worst single sample: 2.2 pCi/L | 6/6 | SYR4 | 2012–2018 |
| Lithium | 31.9 µg/L No EPA limit set | 5/12 | UCMR-5 | 2025 |
| Simazine | 0.0980 µg/L 2.5% of the EPA limit 4 µg/L
worst single sample: 0.1000 µg/L | 3/20 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 0.7900 µg/L 13% of the EPA limit 6 µg/L
worst single sample: 0.8000 µg/L | 2/20 | SYR4 | 2012–2019 |
| Xylenes, Total | 17.397 µg/L 0.2% of the EPA limit 10000 µg/L
worst single sample: 18.2 µg/L | 2/20 | SYR4 | 2012–2019 |
| Ethylbenzene | 2.73 µg/L 0.4% of the EPA limit 700 µg/L | 1/20 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 4.1 pCi/L No EPA limit set | 1/6 | SYR4 | 2012–2018 |
81 contaminants tested, none detected
Utility contact
Frequently asked questions about City of Anna
Is City of Anna tap water safe to drink?
EPA monitoring detected 28 contaminants in City of Anna's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in City of Anna's water?
EPA monitoring detected Copper, Lead, Nitrate, Dibromochloromethane, Bromoform, and others. The full list with the level and data source for each is above.
How many people does City of Anna serve?
City of Anna reports serving 23,960 people in Texas, per its EPA record.
Has City of Anna had any water quality violations?
The EPA has 68 violations on file for City of Anna, of which 9 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.