← Texas

Tap water quality report

Alto Rural Wsc Central High Plant

EPA monitoring tested this supplier for 108 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
21
detected
1,305
people served
21
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Cherokee

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

21
health-based violations
108
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-01-01 → 2019-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
21.46 µg/L
No EPA limit set
worst single sample: 25.9 µg/L
55/55 SYR4 2012–2019
Chloroform
53.53 µg/L
No EPA limit set
worst single sample: 80.5 µg/L
55/55 SYR4 2012–2019
Dibromochloromethane
25.34 µg/L
No EPA limit set
worst single sample: 31 µg/L
55/55 SYR4 2012–2019
Copper
1210 µg/L 93%
of the EPA limit 1300 µg/L
worst single sample: 1640 µg/L
48/50 SYR4 2015–2019
Dichloroacetic Acid
23.95 µg/L
No EPA limit set
worst single sample: 27.7 µg/L
46/46 SYR4 2012–2019
TTHM
81.35 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 108 µg/L
46/46 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
59.3 µg/L 99%
of the EPA limit 60 µg/L
worst single sample: 64.9 µg/L
46/46 SYR4 2012–2019
Trichloroacetic Acid
31.925 µg/L
No EPA limit set
worst single sample: 35.4 µg/L
46/46 SYR4 2012–2019
Dibromoacetic Acid
7.67 µg/L
No EPA limit set
worst single sample: 8.3 µg/L
32/46 SYR4 2012–2019
Bromoform
12.085 µg/L
No EPA limit set
worst single sample: 18.7 µg/L
24/55 SYR4 2012–2019
Lead
2.41 µg/L 16%
of the EPA limit 15 µg/L
worst single sample: 7.97 µg/L
17/50 SYR4 2015–2019
Monochloroacetic Acid
5.44 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
17/46 SYR4 2012–2019
Nitrate
48.5 µg/L 0.5%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Monobromoacetic Acid
1.58 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
9/46 SYR4 2012–2019
Lead
0.0010 mg/L 6.9%
of the EPA limit 0.0150 mg/L
5/5 LCR 2027
Fluoride
658.9 µg/L 16%
of the EPA limit 4000 µg/L
worst single sample: 660 µg/L
3/3 SYR4 2012–2018
Nitrate-Nitrite
44.89 µg/L 0.4%
of the EPA limit 10000 µg/L
worst single sample: 45 µg/L
3/3 SYR4 2013–2019
Barium
4.185 µg/L 0.2%
of the EPA limit 2000 µg/L
worst single sample: 4.2 µg/L
2/2 SYR4 2015–2018
Cyanide
13 µg/L 6.5%
of the EPA limit 200 µg/L
1/3 SYR4 2012–2018
Carbon Tetrachloride
0.7300 µg/L 15%
of the EPA limit 5 µg/L
1/9 SYR4 2012–2019
Xylenes, Total
1.01 µg/L 0%
of the EPA limit 10000 µg/L
1/9 SYR4 2012–2019
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BLACK, TERRY
Phone
936-858-4658

Frequently asked questions about Alto Rural Wsc Central High Plant

Is Alto Rural Wsc Central High Plant tap water safe to drink?

EPA monitoring detected 21 contaminants in Alto Rural Wsc Central High Plant's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Alto Rural Wsc Central High Plant's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Copper, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Alto Rural Wsc Central High Plant serve?

Alto Rural Wsc Central High Plant reports serving 1,305 people in Texas, per its EPA record.

Has Alto Rural Wsc Central High Plant had any water quality violations?

The EPA has 108 violations on file for Alto Rural Wsc Central High Plant, of which 21 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.