← Texas

Tap water quality report

Newsome Wsc

EPA monitoring tested this supplier for 79 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
16
detected
585
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Camp

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
107
violations on file
4
still open
ViolationTypeStatusPeriod
MR Monitoring Unaddressed 2025-12-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
Other Monitoring Unaddressed 2025-06-30
MR Monitoring Resolved 2024-01-01 → 2024-03-31
MR Monitoring Resolved 2024-01-01 → 2024-03-31
MR Monitoring Resolved 2024-01-01 → 2024-03-31
Other Monitoring Resolved 2022-06-25
Other Monitoring Resolved 2022-06-25

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
359 µg/L 28%
of the EPA limit 1300 µg/L
worst single sample: 460 µg/L
22/26 SYR4 2016–2019
Nitrate
70 µg/L 0.7%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromodichloromethane
5.777 µg/L
No EPA limit set
worst single sample: 6.54 µg/L
8/8 SYR4 2013–2019
Chloroform
10.0945 µg/L
No EPA limit set
worst single sample: 12.1 µg/L
8/8 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
6/6 LCR 2025
Dibromochloromethane
2.815 µg/L
No EPA limit set
worst single sample: 2.92 µg/L
4/8 SYR4 2013–2019
Dichloroacetic Acid
5.64 µg/L
No EPA limit set
worst single sample: 6 µg/L
3/3 SYR4 2013–2019
Fluoride
210.4 µg/L 5.3%
of the EPA limit 4000 µg/L
worst single sample: 220 µg/L
3/3 SYR4 2012–2018
Lead
2.34 µg/L 16%
of the EPA limit 15 µg/L
worst single sample: 2.4 µg/L
3/26 SYR4 2016–2019
Nitrate-Nitrite
42.11 µg/L 0.4%
of the EPA limit 10000 µg/L
worst single sample: 42.4 µg/L
3/3 SYR4 2013–2019
TTHM
20.74 µg/L 26%
of the EPA limit 80 µg/L
worst single sample: 21.6 µg/L
3/3 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
8.84 µg/L 15%
of the EPA limit 60 µg/L
worst single sample: 9.3 µg/L
3/3 SYR4 2013–2019
Trichloroacetic Acid
3.2 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
3/3 SYR4 2013–2019
Barium
18.95 µg/L 0.9%
of the EPA limit 2000 µg/L
worst single sample: 19 µg/L
2/2 SYR4 2016–2019
Chromium
1.2 µg/L 1.2%
of the EPA limit 100 µg/L
1/2 SYR4 2016–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HAMBLIN, DAVID
Phone
903-856-5840

Frequently asked questions about Newsome Wsc

Is Newsome Wsc tap water safe to drink?

EPA monitoring detected 16 contaminants in Newsome Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Newsome Wsc's water?

EPA monitoring detected Copper, Nitrate, Bromodichloromethane, Chloroform, Lead, and others. The full list with the level and data source for each is above.

How many people does Newsome Wsc serve?

Newsome Wsc reports serving 585 people in Texas, per its EPA record.

Has Newsome Wsc had any water quality violations?

The EPA has 107 violations on file for Newsome Wsc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.