← Texas

Tap water quality report

Coronado Shores Water

EPA monitoring tested this supplier for 79 contaminants and detected 28. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
28
detected
85
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Briscoe

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
49
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
Other Monitoring Resolved 2025-05-01
Other Monitoring Resolved 2025-05-01
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
46.5 µg/L 0.5%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
45.145 µg/L 3.5%
of the EPA limit 1300 µg/L
worst single sample: 67.7 µg/L
14/17 SYR4 2012–2018
Bromoform
14.067 µg/L
No EPA limit set
worst single sample: 17.4 µg/L
7/8 SYR4 2012–2019
Dibromochloromethane
6.774 µg/L
No EPA limit set
worst single sample: 6.9 µg/L
4/8 SYR4 2012–2019
Fluoride
2738.5 µg/L 68%
of the EPA limit 4000 µg/L
worst single sample: 2740 µg/L
4/4 SYR4 2012–2019
Lead
2.027 µg/L 14%
of the EPA limit 15 µg/L
worst single sample: 2.12 µg/L
4/17 SYR4 2012–2018
Barium
14.81 µg/L 0.7%
of the EPA limit 2000 µg/L
worst single sample: 14.9 µg/L
3/3 SYR4 2012–2019
Bromodichloromethane
3.116 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
3/8 SYR4 2012–2019
Nitrate-Nitrite
38.4 µg/L 0.4%
of the EPA limit 10000 µg/L
worst single sample: 40 µg/L
3/3 SYR4 2012–2015
Chromium
6.225 µg/L 6.2%
of the EPA limit 100 µg/L
worst single sample: 6.4 µg/L
2/3 SYR4 2012–2019
Combined Radium (-226 And -228)
1.0735 pCi/L 21%
of the EPA limit 5 pCi/L
worst single sample: 1.08 pCi/L
2/3 SYR4 2013–2019
Combined Uranium
2.8 µg/L 9.3%
of the EPA limit 30 µg/L
2/2 SYR4 2016–2019
Di(2-ethylhexyl) Phthalate
0.6900 µg/L 12%
of the EPA limit 6 µg/L
worst single sample: 0.7000 µg/L
2/7 SYR4 2014–2019
Dibromoacetic Acid
3.11 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
2/2 SYR4 2016–2019
Gross Alpha, Excl. Radon And U
6.95 pCi/L 46%
of the EPA limit 15 pCi/L
worst single sample: 7 pCi/L
2/2 SYR4 2016–2019
Gross Beta Particle Activity
4.57 pCi/L
No EPA limit set
worst single sample: 4.6 pCi/L
2/3 SYR4 2013–2019
TTHM
9.786 µg/L 12%
of the EPA limit 80 µg/L
worst single sample: 9.97 µg/L
2/2 SYR4 2016–2019
Total Haloacetic Acids (HAA5)
8.62 µg/L 14%
of the EPA limit 60 µg/L
worst single sample: 9 µg/L
2/2 SYR4 2016–2019
Arsenic
3 µg/L 30%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2019
Bhc-Gamma
0.0300 µg/L 15%
of the EPA limit 0.2000 µg/L
1/7 SYR4 2014–2019
Cyanide
11 µg/L 5.5%
of the EPA limit 200 µg/L
1/2 SYR4 2014–2017
Chloroform
1.8 µg/L
No EPA limit set
1/8 SYR4 2012–2019
Endrin
0.0400 µg/L 2%
of the EPA limit 2 µg/L
1/7 SYR4 2014–2019
Heptachlor Epoxide
0.1000 µg/L 50%
of the EPA limit 0.2000 µg/L
1/7 SYR4 2014–2019
Lead
0.00073 mg/L 4.9%
of the EPA limit 0.0150 mg/L
1/1 LCR 2024
Monochloroacetic Acid
5.8 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Selenium
10.8 µg/L 22%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2019
Xylenes, Total
1.13 µg/L 0%
of the EPA limit 10000 µg/L
1/6 SYR4 2012–2019
51 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDichloroacetic AcidDinosebEthylene DibromideEthylbenzeneHexachlorobenzeneHeptachlorHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JOHNSON, JEFFREY
Phone
806-633-4326
Email
wateroperator@midplains.coop

Frequently asked questions about Coronado Shores Water

Is Coronado Shores Water tap water safe to drink?

EPA monitoring detected 28 contaminants in Coronado Shores Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Coronado Shores Water's water?

EPA monitoring detected Nitrate, Copper, Bromoform, Dibromochloromethane, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Coronado Shores Water serve?

Coronado Shores Water reports serving 85 people in Texas, per its EPA record.

Has Coronado Shores Water had any water quality violations?

The EPA has 49 violations on file for Coronado Shores Water, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.