Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfba | 0.0052 µg/L | 1/6 | 2025 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1700 µg/L 131% of the EPA limit, in the worst sample — 1300 µg/L | 122/124 | SYR4 | 2013–2018 |
| Bromodichloromethane | 85.8 µg/L No EPA limit set | 80/80 | SYR4 | 2012–2019 |
| Chloroform | 283 µg/L No EPA limit set | 79/80 | SYR4 | 2012–2019 |
| Dibromochloromethane | 82.4 µg/L No EPA limit set | 76/80 | SYR4 | 2012–2019 |
| Bromoform | 88 µg/L No EPA limit set | 75/80 | SYR4 | 2012–2019 |
| Nitrate | 850 µg/L 8.5% of the EPA limit 10000 µg/L | 62/64 | SYR4 | 2012–2019 |
| TTHM | 403 µg/L 504% of the EPA limit, in the worst sample — 80 µg/L | 61/61 | SYR4 | 2012–2019 |
| Lead | 39 µg/L 260% of the EPA limit, in the worst sample — 15 µg/L | 51/124 | SYR4 | 2013–2018 |
| Total Haloacetic Acids (HAA5) | 118 µg/L 197% of the EPA limit, in the worst sample — 60 µg/L | 44/62 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 74.2 µg/L No EPA limit set | 43/62 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 31 µg/L No EPA limit set | 40/62 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 75.1 µg/L No EPA limit set | 38/62 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 4.9 µg/L No EPA limit set | 17/62 | SYR4 | 2012–2019 |
| Lead | 0.0025 mg/L 17% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2023 |
| Nitrate-Nitrite | 850 µg/L 8.5% of the EPA limit 10000 µg/L | 14/14 | SYR4 | 2012–2015 |
| Atrazine | 0.2200 µg/L 7.3% of the EPA limit 3 µg/L | 9/22 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 15.2 µg/L No EPA limit set | 9/62 | SYR4 | 2012–2019 |
| Xylenes, Total | 3.6 µg/L 0% of the EPA limit 10000 µg/L | 9/19 | SYR4 | 2014–2019 |
| Lithium | 133 µg/L No EPA limit set | 9/9 | UCMR-5 | 2025 |
| Barium | 46.7 µg/L 2.3% of the EPA limit 2000 µg/L | 4/4 | SYR4 | 2014–2017 |
| Fluoride | 1480 µg/L 37% of the EPA limit 4000 µg/L | 4/4 | SYR4 | 2014–2017 |
| Dalapon | 3.2 µg/L 1.6% of the EPA limit 200 µg/L | 3/56 | SYR4 | 2012–2019 |
| Selenium | 5.9 µg/L 12% of the EPA limit 50 µg/L | 3/4 | SYR4 | 2014–2017 |
| Arsenic | 2.3 µg/L 23% of the EPA limit 10 µg/L | 2/4 | SYR4 | 2014–2017 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 2/2 | SYR4 | 2016 |
| Ethylbenzene | 0.5000 µg/L 0.1% of the EPA limit 700 µg/L | 1/19 | SYR4 | 2014–2019 |
| Gross Alpha, Excl. Radon And U | 5.4 pCi/L 36% of the EPA limit 15 pCi/L | 1/2 | SYR4 | 2016 |
| Nitrite | 10 µg/L 1% of the EPA limit 1000 µg/L | 1/14 | SYR4 | 2012–2015 |
80 contaminants tested, none detected
Utility contact
Frequently asked questions about Bell Milam Falls Wsc
Is Bell Milam Falls Wsc tap water safe to drink?
EPA monitoring detected 29 contaminants in Bell Milam Falls Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Bell Milam Falls Wsc's water?
EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Bromoform, and others. The full list with the level and data source for each is above.
How many people does Bell Milam Falls Wsc serve?
Bell Milam Falls Wsc reports serving 6,885 people in Texas, per its EPA record.
Has Bell Milam Falls Wsc had any water quality violations?
The EPA has 167 violations on file for Bell Milam Falls Wsc, of which 75 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.