← Tennessee

Tap water quality report

Pigeon Forge Water Department

EPA monitoring tested this supplier for 60 contaminants and detected 4. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

60
contaminants tested
4
detected
14,872
people served
3
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Sevier

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
38
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2010-10-02
TT Health-based Resolved 2010-10-02
TT Health-based Resolved 2010-10-02
MR Monitoring Resolved 2008-10-01 → 2008-11-30
MR Monitoring Resolved 2008-10-01 → 2008-11-30
MR Monitoring Resolved 2008-10-01 → 2008-11-30
MR Monitoring Resolved 2008-10-01 → 2008-11-30
MR Monitoring Resolved 2008-10-01 → 2008-11-30
MR Monitoring Resolved 2008-10-01 → 2008-11-30
MR Monitoring Resolved 2008-10-01 → 2008-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
75.6 µg/L 95%
of the EPA limit 80 µg/L
96/96 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
43.9 µg/L 73%
of the EPA limit 60 µg/L
96/96 SYR4 2014–2019
Nitrate
585 µg/L 5.9%
of the EPA limit 10000 µg/L
12/12 SYR4 2014–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAtrazineBenzeneChlorobenzeneCarbon TetrachlorideDichloromethaneEthylbenzeneGross Alpha, Excl. Radon And UHfpo-DaNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPicloramSimazineStyreneTetrachloroethyleneTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCMAHAN, KEVIN
Phone
865-453-1275
Email
kevin.mcmahan@cityofpigeonforgetn.gov

Frequently asked questions about Pigeon Forge Water Department

Is Pigeon Forge Water Department tap water safe to drink?

EPA monitoring detected 4 contaminants in Pigeon Forge Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pigeon Forge Water Department's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Lead. The full list with the level and data source for each is above.

How many people does Pigeon Forge Water Department serve?

Pigeon Forge Water Department reports serving 14,872 people in Tennessee, per its EPA record.

Has Pigeon Forge Water Department had any water quality violations?

The EPA has 38 violations on file for Pigeon Forge Water Department, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.