← South Dakota

Tap water quality report

Prairie Acres South

EPA monitoring tested this supplier for 21 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

21
contaminants tested
8
detected
170
people served
14
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Pennington

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

14
health-based violations
277
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2019-10-08
TT Health-based Resolved 2019-10-08
TT Health-based Resolved 2015-02-01
TT Health-based Resolved 2015-02-01
TT Health-based Resolved 2011-03-08
TT Health-based Resolved 2011-03-08
TT Health-based Resolved 2009-01-01
TT Health-based Resolved 2009-01-01
MCL Health-based Resolved 2008-11-01 → 2008-11-30
MCL Health-based Resolved 2008-11-01 → 2008-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
235 µg/L 18%
of the EPA limit 1300 µg/L
15/15 SYR4 2012–2018
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Lead
4 µg/L 27%
of the EPA limit 15 µg/L
15/15 SYR4 2012–2018
Nitrate
626 µg/L 6.3%
of the EPA limit 10000 µg/L
6/6 SYR4 2017–2019
Barium
31 µg/L 1.6%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Fluoride
400 µg/L 10%
of the EPA limit 4000 µg/L
1/1 SYR4 2012
Gross Alpha, Excl. Radon And U
8.37 pCi/L 56%
of the EPA limit 15 pCi/L
1/1 SYR4 2018
Selenium
8 µg/L 16%
of the EPA limit 50 µg/L
1/1 SYR4 2012
13 contaminants tested, none detected
Antimony, TotalArsenicBeryllium, TotalCadmiumChromiumCombined Radium (-226 And -228)Combined UraniumGross Beta Particle ActivityMercuryNitriteTTHMThallium, TotalTotal Haloacetic Acids (HAA5)

Utility contact

Contact
BRANDON POWLES
Email
brandonpowles@yahoo.com

Frequently asked questions about Prairie Acres South

Is Prairie Acres South tap water safe to drink?

EPA monitoring detected 8 contaminants in Prairie Acres South's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Prairie Acres South's water?

EPA monitoring detected Copper, Lead, Lead, Nitrate, Barium, and others. The full list with the level and data source for each is above.

How many people does Prairie Acres South serve?

Prairie Acres South reports serving 170 people in South Dakota, per its EPA record.

Has Prairie Acres South had any water quality violations?

The EPA has 277 violations on file for Prairie Acres South, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.