Tap water quality report

Mccormick Co W&Sa (sc3520002)

EPA monitoring tested this supplier for 44 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
18
detected
8,500
people served
85
health-based violations
Water source
SWP
Ownership
Local government
Counties served
McCormick

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

85
health-based violations
118
violations on file
8
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOS 0.0088 µg/L 4/12 2023
PFBS 0.0049 µg/L 2/12 2023
Hfpo-Da 0.0066 µg/L 1/12 2023
Pfhxa 0.0034 µg/L 1/12 2023
Pfpea 0.0034 µg/L 1/12 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
263 µg/L 20%
of the EPA limit 1300 µg/L
58/60 SYR4 2013–2019
Bromodichloromethane
15 µg/L
No EPA limit set
48/48 SYR4 2013–2019
Chloroform
100.9 µg/L
No EPA limit set
48/48 SYR4 2013–2019
Dichloroacetic Acid
36.6 µg/L
No EPA limit set
48/48 SYR4 2013–2019
TTHM
116.4 µg/L 146%
of the EPA limit, in the worst sample — 80 µg/L
48/48 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
78.7 µg/L 131%
of the EPA limit, in the worst sample — 60 µg/L
48/48 SYR4 2013–2019
Trichloroacetic Acid
42.1 µg/L
No EPA limit set
46/48 SYR4 2013–2019
Dibromochloromethane
3.3 µg/L
No EPA limit set
45/48 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
18/18 LCR 2025
Lead
10 µg/L 67%
of the EPA limit 15 µg/L
12/60 SYR4 2013–2019
Dibromoacetic Acid
1.2 µg/L
No EPA limit set
5/48 SYR4 2013–2019
Bromoform
4.6 µg/L
No EPA limit set
2/48 SYR4 2013–2019
Monochloroacetic Acid
2.3 µg/L
No EPA limit set
2/48 SYR4 2013–2019
26 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
UPCHURCH, JAMES
Phone
864-852-2231
Email
JUPCHURCH@MCCORMICKCOUNTYSC.ORG; SWILSON@MCCORMICKCOUNTYSC.GOV

Frequently asked questions about Mccormick Co W&Sa (sc3520002)

Is Mccormick Co W&Sa (sc3520002) tap water safe to drink?

EPA monitoring detected 18 contaminants in Mccormick Co W&Sa (sc3520002)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Mccormick Co W&Sa (sc3520002)'s water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Mccormick Co W&Sa (sc3520002) serve?

Mccormick Co W&Sa (sc3520002) reports serving 8,500 people in South Carolina, per its EPA record.

Has Mccormick Co W&Sa (sc3520002) had any water quality violations?

The EPA has 118 violations on file for Mccormick Co W&Sa (sc3520002), of which 85 are health-based (a contaminant limit or required treatment was breached) and 8 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.