← South Carolina

Tap water quality report

Gsw&Sa-Myrtle Beach (sc2620009)

EPA monitoring tested this supplier for 76 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
17
detected
25
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Horry

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
2
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2019-10-01
MR Monitoring Resolved 2019-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
260 µg/L 2.6%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
1195 µg/L 92%
of the EPA limit 1300 µg/L
worst single sample: 2000 µg/L
15/15 SYR4 2013–2019
Bromodichloromethane
14.9895 µg/L
No EPA limit set
worst single sample: 17.18 µg/L
14/14 SYR4 2013–2019
Chloroform
25.8815 µg/L
No EPA limit set
worst single sample: 31.01 µg/L
14/14 SYR4 2013–2019
Dibromochloromethane
6.3215 µg/L
No EPA limit set
worst single sample: 9.5 µg/L
14/14 SYR4 2013–2019
Dichloroacetic Acid
27.867 µg/L
No EPA limit set
worst single sample: 34.9 µg/L
14/14 SYR4 2013–2019
TTHM
45.7685 µg/L 57%
of the EPA limit 80 µg/L
worst single sample: 48.31 µg/L
14/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
43.295 µg/L 72%
of the EPA limit 60 µg/L
worst single sample: 45.7 µg/L
14/14 SYR4 2013–2019
Monobromoacetic Acid
7.52 µg/L
No EPA limit set
worst single sample: 10.01 µg/L
13/14 SYR4 2013–2019
Trichloroacetic Acid
13.889 µg/L
No EPA limit set
worst single sample: 15.55 µg/L
12/14 SYR4 2013–2019
Lead
18.64 µg/L 124%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 25 µg/L
9/15 SYR4 2013–2019
Lead
0.0140 mg/L 93%
of the EPA limit 0.0150 mg/L
8/8 LCR 2023
Fluoride
786 µg/L 20%
of the EPA limit 4000 µg/L
worst single sample: 900 µg/L
7/8 SYR4 2012–2019
Dibromoacetic Acid
7.2325 µg/L
No EPA limit set
worst single sample: 7.4 µg/L
6/14 SYR4 2013–2019
Atrazine
0.2595 µg/L 8.7%
of the EPA limit 3 µg/L
worst single sample: 0.2600 µg/L
2/10 SYR4 2012–2019
Chromium
5.7 µg/L 5.7%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Nitrate-Nitrite
260 µg/L 2.6%
of the EPA limit 10000 µg/L
1/1 SYR4 2012
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromateBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PATEL, NEERAJ
Phone
843-443-8251
Email
CHANDLERRICHARDSON@GSWSA.COM; NPATEL@GSWSA.COM; ssperbeck@gswsa.com; ROBBYTODD@GSWSA.COM

Frequently asked questions about Gsw&Sa-Myrtle Beach (sc2620009)

Is Gsw&Sa-Myrtle Beach (sc2620009) tap water safe to drink?

EPA monitoring detected 17 contaminants in Gsw&Sa-Myrtle Beach (sc2620009)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Gsw&Sa-Myrtle Beach (sc2620009)'s water?

EPA monitoring detected Nitrate, Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Gsw&Sa-Myrtle Beach (sc2620009) serve?

Gsw&Sa-Myrtle Beach (sc2620009) reports serving 25 people in South Carolina, per its EPA record.

Has Gsw&Sa-Myrtle Beach (sc2620009) had any water quality violations?

The EPA has 2 violations on file for Gsw&Sa-Myrtle Beach (sc2620009), of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.