← Pennsylvania

Tap water quality report

Fairmount Home

EPA monitoring tested this supplier for 78 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
10
detected
483
people served
14
health-based violations
Water source
Ground water
Ownership
Mixed public/private
Counties served
Lancaster

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

14
health-based violations
154
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2004-04-01 → 2004-06-30
MCL Health-based Resolved 1994-01-01 → 1994-12-31
MCL Health-based Archived 1987-04-29 → 1987-05-28
MCL Health-based Archived 1986-10-20 → 1986-11-19
MCL Health-based Archived 1986-04-18 → 1986-05-17
MCL Health-based Archived 1985-10-16 → 1985-11-15

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
6310 µg/L 63%
of the EPA limit 10000 µg/L
worst single sample: 23390 µg/L
66/66 SYR4 2012–2019
Copper
1111.4 µg/L 85%
of the EPA limit 1300 µg/L
worst single sample: 1278 µg/L
15/15 SYR4 2013–2019
Bromodichloromethane
1.58 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
5/5 SYR4 2013–2018
Bromoform
4 µg/L
No EPA limit set
5/5 SYR4 2013–2018
Dibromochloromethane
3.16 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
5/5 SYR4 2013–2018
TTHM
9.105 µg/L 11%
of the EPA limit 80 µg/L
worst single sample: 9.3 µg/L
4/4 SYR4 2013–2018
Chloroform
0.8800 µg/L
No EPA limit set
worst single sample: 0.9000 µg/L
2/4 SYR4 2013–2018
Lead
0.0045 mg/L 30%
of the EPA limit 0.0150 mg/L
2/2 LCR 1996
Dichloromethane
0.7000 µg/L 14%
of the EPA limit 5 µg/L
1/6 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
1 µg/L 1.7%
of the EPA limit 60 µg/L
1/4 SYR4 2013–2018
68 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JOHN BECKER
Phone
717-354-1800

Frequently asked questions about Fairmount Home

Is Fairmount Home tap water safe to drink?

EPA monitoring detected 10 contaminants in Fairmount Home's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Fairmount Home's water?

EPA monitoring detected Nitrate, Copper, Bromodichloromethane, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Fairmount Home serve?

Fairmount Home reports serving 483 people in Pennsylvania, per its EPA record.

Has Fairmount Home had any water quality violations?

The EPA has 154 violations on file for Fairmount Home, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.