Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2018-02-01 → 2018-02-28 |
| TT | Health-based | Resolved | 2018-02-01 → 2018-02-28 |
| MCL | Health-based | Resolved | 2015-09-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-09-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2004-08-01 → 2004-08-31 |
| MCL | Health-based | Resolved | 2004-08-01 → 2004-08-31 |
| TT | Health-based | Resolved | 2004-02-01 → 2004-02-29 |
| TT | Health-based | Archived | 1992-05-01 → 1992-05-31 |
| TT | Health-based | Archived | 1991-07-01 → 1991-07-31 |
| MR | Monitoring | Unaddressed | 2025-07-01 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| 6:2 Fts | 0.0097 µg/L | 1/8 | 2025 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 250 µg/L 19% of the EPA limit 1300 µg/L | 228/241 | SYR4 | 2013–2019 |
| Chloroform | 75.3 µg/L No EPA limit set | 154/154 | SYR4 | 2012–2019 |
| Bromodichloromethane | 30 µg/L No EPA limit set | 145/146 | SYR4 | 2012–2019 |
| TTHM | 80.6 µg/L 101% of the EPA limit, in the worst sample — 80 µg/L | 144/144 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 96.3 µg/L 161% of the EPA limit, in the worst sample — 60 µg/L | 142/143 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 42 µg/L No EPA limit set | 101/101 | SYR4 | 2013–2019 |
| Dibromochloromethane | 3 µg/L No EPA limit set | 99/142 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 59 µg/L No EPA limit set | 98/101 | SYR4 | 2013–2019 |
| Nitrate | 4020 µg/L 40% of the EPA limit 10000 µg/L | 20/20 | SYR4 | 2012–2019 |
| Lead | 0.0039 mg/L 26% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2022 |
| Lead | 125 µg/L 833% of the EPA limit, in the worst sample — 15 µg/L | 16/241 | SYR4 | 2013–2019 |
| Fluoride | 1170 µg/L 29% of the EPA limit 4000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Barium | 70 µg/L 3.5% of the EPA limit 2000 µg/L | 6/8 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 1000 µg/L No EPA limit set | 5/101 | SYR4 | 2013–2019 |
| Lithium | 19 µg/L No EPA limit set | 4/8 | UCMR-5 | 2025 |
| Xylenes, Total | 1.5 µg/L 0% of the EPA limit 10000 µg/L | 2/13 | SYR4 | 2012–2019 |
| Bromoform | 3 µg/L No EPA limit set | 1/143 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 32 µg/L No EPA limit set | 1/101 | SYR4 | 2013–2019 |
91 contaminants tested, none detected
Utility contact
Frequently asked questions about Bear Valley Joint Auth
Is Bear Valley Joint Auth tap water safe to drink?
EPA monitoring detected 19 contaminants in Bear Valley Joint Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Bear Valley Joint Auth's water?
EPA monitoring detected Copper, Chloroform, Bromodichloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Bear Valley Joint Auth serve?
Bear Valley Joint Auth reports serving 12,589 people in Pennsylvania, per its EPA record.
Has Bear Valley Joint Auth had any water quality violations?
The EPA has 253 violations on file for Bear Valley Joint Auth, of which 9 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.