Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2018-01-01 → 2018-03-31 |
| MCL | Health-based | Resolved | 2018-01-01 → 2018-03-31 |
| MCL | Health-based | Resolved | 2018-01-01 → 2018-03-31 |
| MCL | Health-based | Resolved | 2018-01-01 → 2018-03-31 |
| TT | Health-based | Resolved | 2017-12-11 |
| TT | Health-based | Resolved | 2017-12-11 |
| TT | Health-based | Resolved | 2017-12-11 |
| TT | Health-based | Resolved | 2017-12-11 |
| MCL | Health-based | Resolved | 2017-10-01 → 2017-12-31 |
| MCL | Health-based | Resolved | 2017-10-01 → 2017-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 27.4 µg/L No EPA limit set | 86/86 | SYR4 | 2012–2019 |
| Chloroform | 150 µg/L No EPA limit set | 86/86 | SYR4 | 2012–2019 |
| TTHM | 171 µg/L 214% of the EPA limit, in the worst sample — 80 µg/L | 85/85 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 246 µg/L 410% of the EPA limit, in the worst sample — 60 µg/L | 81/81 | SYR4 | 2012–2019 |
| Dibromochloromethane | 9.1 µg/L No EPA limit set | 79/85 | SYR4 | 2012–2019 |
| Copper | 360 µg/L 28% of the EPA limit 1300 µg/L | 60/60 | SYR4 | 2013–2019 |
| Nitrate | 1700 µg/L 17% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 53 µg/L No EPA limit set | 15/15 | SYR4 | 2018–2019 |
| Trichloroacetic Acid | 39 µg/L No EPA limit set | 15/15 | SYR4 | 2018–2019 |
| Lead | 0.0017 mg/L 11% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2024 |
| Barium | 28 µg/L 1.4% of the EPA limit 2000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Lead | 17 µg/L 113% of the EPA limit, in the worst sample — 15 µg/L | 8/60 | SYR4 | 2013–2019 |
| Bromoform | 1.2 µg/L No EPA limit set | 7/82 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 9.3 µg/L No EPA limit set | 7/15 | SYR4 | 2018–2019 |
| Dibromoacetic Acid | 4.4 µg/L No EPA limit set | 2/15 | SYR4 | 2018–2019 |
| Cyanide | 4.1 µg/L 2.1% of the EPA limit 200 µg/L | 1/8 | SYR4 | 2012–2019 |
| Hexachlorocyclopentadiene | 0.2200 µg/L 0.4% of the EPA limit 50 µg/L | 1/8 | SYR4 | 2014–2019 |
| Monobromoacetic Acid | 1 µg/L No EPA limit set | 1/15 | SYR4 | 2018–2019 |
| Selenium | 6.9 µg/L 14% of the EPA limit 50 µg/L | 1/8 | SYR4 | 2012–2019 |
91 contaminants tested, none detected
Utility contact
Frequently asked questions about Pa American Water Steelton
Is Pa American Water Steelton tap water safe to drink?
EPA monitoring detected 19 contaminants in Pa American Water Steelton's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Pa American Water Steelton's water?
EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Pa American Water Steelton serve?
Pa American Water Steelton reports serving 6,428 people in Pennsylvania, per its EPA record.
Has Pa American Water Steelton had any water quality violations?
The EPA has 225 violations on file for Pa American Water Steelton, of which 131 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.