← Pennsylvania

Tap water quality report

Girard Boro Water Dept

EPA monitoring tested this supplier for 110 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
15
detected
3,301
people served
14
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Erie

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

14
health-based violations
1,016
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2012-02-01 → 2012-02-29
TT Health-based Resolved 2012-02-01 → 2012-02-29
TT Health-based Resolved 2012-02-01 → 2012-02-29
TT Health-based Resolved 2012-02-01 → 2012-02-29
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
403.25 µg/L 31%
of the EPA limit 1300 µg/L
worst single sample: 4700 µg/L
80/80 SYR4 2013–2019
Nitrate
6602.5 µg/L 66%
of the EPA limit 10000 µg/L
worst single sample: 9100 µg/L
66/88 SYR4 2012–2019
TTHM
13.205 µg/L 17%
of the EPA limit 80 µg/L
worst single sample: 13.7 µg/L
10/10 SYR4 2012–2019
Bromodichloromethane
4.576 µg/L
No EPA limit set
worst single sample: 4.94 µg/L
9/10 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Dibromochloromethane
4.3295 µg/L
No EPA limit set
worst single sample: 4.34 µg/L
8/10 SYR4 2012–2019
Chloroform
4.63 µg/L
No EPA limit set
worst single sample: 5.08 µg/L
7/10 SYR4 2012–2019
Barium
164.25 µg/L 8.2%
of the EPA limit 2000 µg/L
worst single sample: 169 µg/L
6/9 SYR4 2012–2018
Bromoform
1.8165 µg/L
No EPA limit set
worst single sample: 1.86 µg/L
4/10 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
19.383 µg/L 32%
of the EPA limit 60 µg/L
worst single sample: 22.2 µg/L
4/10 SYR4 2012–2019
Lead
19.32 µg/L 129%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 21 µg/L
3/59 SYR4 2013–2019
Dichloroacetic Acid
5.7775 µg/L
No EPA limit set
worst single sample: 5.98 µg/L
2/2 SYR4 2015–2019
Dibromoacetic Acid
2.6 µg/L
No EPA limit set
1/2 SYR4 2015–2019
Fluoride
110 µg/L 2.8%
of the EPA limit 4000 µg/L
1/9 SYR4 2012–2018
Monobromoacetic Acid
13.6 µg/L
No EPA limit set
1/2 SYR4 2015–2019
95 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROBERT STUBENBOR
Phone
814-774-9683

Frequently asked questions about Girard Boro Water Dept

Is Girard Boro Water Dept tap water safe to drink?

EPA monitoring detected 15 contaminants in Girard Boro Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Girard Boro Water Dept's water?

EPA monitoring detected Copper, Nitrate, TTHM, Bromodichloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does Girard Boro Water Dept serve?

Girard Boro Water Dept reports serving 3,301 people in Pennsylvania, per its EPA record.

Has Girard Boro Water Dept had any water quality violations?

The EPA has 1016 violations on file for Girard Boro Water Dept, of which 14 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.