← Pennsylvania

Tap water quality report

Conneaut Lake Park Water

EPA monitoring tested this supplier for 79 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
18
detected
250
people served
149
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Crawford

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

149
health-based violations
512
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-05-12
TT Health-based Unaddressed 2024-05-12
MCL Health-based Resolved 2010-04-01 → 2010-06-30
MCL Health-based Resolved 2010-04-01 → 2010-06-30
MCL Health-based Resolved 2010-04-01 → 2010-06-30
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2009-10-01 → 2009-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Arsenic
23.06 µg/L 231%
of the EPA limit, in the worst sample — 10 µg/L
22/39 SYR4 2012–2019
Copper
180 µg/L 14%
of the EPA limit 1300 µg/L
17/20 SYR4 2013–2019
Lead
48.8 µg/L 325%
of the EPA limit, in the worst sample — 15 µg/L
9/20 SYR4 2013–2019
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
3/3 SYR4 2012–2018
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
3/3 LCR 1996
TTHM
14.6 µg/L 18%
of the EPA limit 80 µg/L
3/4 SYR4 2013–2018
Total Haloacetic Acids (HAA5)
7.8 µg/L 13%
of the EPA limit 60 µg/L
3/4 SYR4 2013–2018
Barium
148 µg/L 7.4%
of the EPA limit 2000 µg/L
2/3 SYR4 2012–2018
Bromodichloromethane
1.5 µg/L
No EPA limit set
2/3 SYR4 2013–2018
Bromoform
0.6300 µg/L
No EPA limit set
2/3 SYR4 2013–2018
Chloroform
0.9100 µg/L
No EPA limit set
2/3 SYR4 2013–2018
Dibromoacetic Acid
610 µg/L
No EPA limit set
2/2 SYR4 2018
Dibromochloromethane
2.2 µg/L
No EPA limit set
2/3 SYR4 2013–2018
Dichloroacetic Acid
720 µg/L
No EPA limit set
2/2 SYR4 2018
Nitrate
5210 µg/L 52%
of the EPA limit 10000 µg/L
2/26 SYR4 2012–2019
Trichloroacetic Acid
800 µg/L
No EPA limit set
2/2 SYR4 2018
Monobromoacetic Acid
1.3 µg/L
No EPA limit set
1/2 SYR4 2018
Monochloroacetic Acid
0.7600 µg/L
No EPA limit set
1/2 SYR4 2018
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TODD JOSEPH
Phone
814-333-2299

Frequently asked questions about Conneaut Lake Park Water

Is Conneaut Lake Park Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Conneaut Lake Park Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Conneaut Lake Park Water's water?

EPA monitoring detected Arsenic, Copper, Lead, Fluoride, Lead, and others. The full list with the level and data source for each is above.

How many people does Conneaut Lake Park Water serve?

Conneaut Lake Park Water reports serving 250 people in Pennsylvania, per its EPA record.

Has Conneaut Lake Park Water had any water quality violations?

The EPA has 512 violations on file for Conneaut Lake Park Water, of which 149 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.