← Pennsylvania

Tap water quality report

Huston Twp Muni Auth

EPA monitoring tested this supplier for 14 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
13
detected
960
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Clearfield

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
167
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 1993-09-01 → 1993-09-30
TT Health-based Resolved 1992-01-01 → 1995-10-01
TT Health-based Archived 1991-08-01 → 1991-08-31
TT Health-based Archived 1991-01-01 → 1991-01-31
MON Monitoring Resolved 2024-08-01 → 2024-08-31
MON Monitoring Resolved 2024-08-01 → 2024-08-31
MON Monitoring Resolved 2024-08-01 → 2024-08-31
MON Monitoring Resolved 2024-08-01 → 2024-08-31
MON Monitoring Resolved 2023-06-01 → 2023-06-30
MON Monitoring Resolved 2023-06-01 → 2023-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1520 µg/L 117%
of the EPA limit, in the worst sample — 1300 µg/L
92/92 SYR4 2013–2019
Lead
157 µg/L 1047%
of the EPA limit, in the worst sample — 15 µg/L
24/92 SYR4 2013–2019
Chloroform
38.2 µg/L
No EPA limit set
14/16 SYR4 2012–2019
TTHM
53.9 µg/L 67%
of the EPA limit 80 µg/L
14/16 SYR4 2012–2019
Bromodichloromethane
12.9 µg/L
No EPA limit set
13/16 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
150 µg/L 250%
of the EPA limit, in the worst sample — 60 µg/L
12/15 SYR4 2012–2019
Dibromochloromethane
20 µg/L
No EPA limit set
10/16 SYR4 2012–2019
Dichloroacetic Acid
15 µg/L
No EPA limit set
7/8 SYR4 2013–2019
Trichloroacetic Acid
23 µg/L
No EPA limit set
7/8 SYR4 2013–2019
Bromoform
12.9 µg/L
No EPA limit set
5/16 SYR4 2012–2019
Lead
0.0437 mg/L 291%
above the EPA limit of 0.0150 mg/L
4/4 LCR 2016
Dibromoacetic Acid
1.2 µg/L
No EPA limit set
1/8 SYR4 2013–2019
Monochloroacetic Acid
120 µg/L
No EPA limit set
1/8 SYR4 2013–2019
1 contaminants tested, none detected
Monobromoacetic Acid

Utility contact

Contact
JEREMY KEPHART
Phone
814-637-5070

Frequently asked questions about Huston Twp Muni Auth

Is Huston Twp Muni Auth tap water safe to drink?

EPA monitoring detected 13 contaminants in Huston Twp Muni Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Huston Twp Muni Auth's water?

EPA monitoring detected Copper, Lead, Chloroform, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Huston Twp Muni Auth serve?

Huston Twp Muni Auth reports serving 960 people in Pennsylvania, per its EPA record.

Has Huston Twp Muni Auth had any water quality violations?

The EPA has 167 violations on file for Huston Twp Muni Auth, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.