← Pennsylvania

Tap water quality report

Icmsa Arcadia

EPA monitoring tested this supplier for 80 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
18
detected
65
people served
210
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Indiana

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

210
health-based violations
809
violations on file
25
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2026-01-01 → 2026-03-31
TT Health-based Resolved 2026-01-01 → 2026-03-31
TT Health-based Resolved 2026-01-01 → 2026-03-31
TT Health-based Resolved 2026-01-01 → 2026-03-31
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
22.7 µg/L
No EPA limit set
22/22 SYR4 2012–2019
Chloroform
97.4 µg/L
No EPA limit set
22/22 SYR4 2012–2019
TTHM
107 µg/L 134%
of the EPA limit, in the worst sample — 80 µg/L
22/22 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
190 µg/L 317%
of the EPA limit, in the worst sample — 60 µg/L
22/22 SYR4 2012–2019
Copper
314 µg/L 24%
of the EPA limit 1300 µg/L
14/19 SYR4 2013–2019
Dibromochloromethane
13.6 µg/L
No EPA limit set
13/22 SYR4 2012–2019
Nitrate
2880 µg/L 29%
of the EPA limit 10000 µg/L
10/16 SYR4 2012–2019
Barium
75 µg/L 3.8%
of the EPA limit 2000 µg/L
7/8 SYR4 2012–2019
Dalapon
2.22 µg/L 1.1%
of the EPA limit 200 µg/L
4/12 SYR4 2013–2019
Bromoform
2 µg/L
No EPA limit set
3/22 SYR4 2012–2019
Dichloroacetic Acid
47 µg/L
No EPA limit set
3/3 SYR4 2015–2019
Lead
0.0545 mg/L 363%
above the EPA limit of 0.0150 mg/L
3/3 LCR 2019
Trichloroacetic Acid
61 µg/L
No EPA limit set
3/3 SYR4 2015–2019
Hexachlorocyclopentadiene
0.2000 µg/L 0.4%
of the EPA limit 50 µg/L
2/12 SYR4 2013–2019
Antimony, Total
0.1000 µg/L 1.7%
of the EPA limit 6 µg/L
1/8 SYR4 2012–2019
Dibromoacetic Acid
4 µg/L
No EPA limit set
1/3 SYR4 2015–2019
Lead
109 µg/L 727%
of the EPA limit, in the worst sample — 15 µg/L
1/15 SYR4 2013–2019
Monochloroacetic Acid
1.62 µg/L
No EPA limit set
1/3 SYR4 2015–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MARTIN MASCHAK
Phone
724-349-6640

Frequently asked questions about Icmsa Arcadia

Is Icmsa Arcadia tap water safe to drink?

EPA monitoring detected 18 contaminants in Icmsa Arcadia's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Icmsa Arcadia's water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Copper, and others. The full list with the level and data source for each is above.

How many people does Icmsa Arcadia serve?

Icmsa Arcadia reports serving 65 people in Pennsylvania, per its EPA record.

Has Icmsa Arcadia had any water quality violations?

The EPA has 809 violations on file for Icmsa Arcadia, of which 210 are health-based (a contaminant limit or required treatment was breached) and 25 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.