← Pennsylvania

Tap water quality report

Edgeworth Boro Muni Auth

EPA monitoring tested this supplier for 44 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
10
detected
7,781
people served
5
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Allegheny

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
22
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2018-04-01 → 2018-06-30
MR Monitoring Resolved 2018-04-01 → 2018-06-30
MR Monitoring Resolved 2018-04-01 → 2018-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
567 µg/L 44%
of the EPA limit 1300 µg/L
83/84 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
84 µg/L 140%
of the EPA limit, in the worst sample — 60 µg/L
60/60 SYR4 2012–2019
Bromodichloromethane
13 µg/L
No EPA limit set
57/58 SYR4 2012–2019
Chloroform
71 µg/L
No EPA limit set
57/58 SYR4 2012–2019
TTHM
82 µg/L 102%
of the EPA limit, in the worst sample — 80 µg/L
57/58 SYR4 2012–2019
Dibromochloromethane
93 µg/L
No EPA limit set
30/58 SYR4 2012–2019
Dichloroacetic Acid
42 µg/L
No EPA limit set
17/17 SYR4 2012–2019
Trichloroacetic Acid
42 µg/L
No EPA limit set
17/17 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Monochloroacetic Acid
24.3 µg/L
No EPA limit set
7/17 SYR4 2012–2019
34 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBromoformDibromoacetic AcidHfpo-DaLeadMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
CHRISTINE HURNI
Phone
412-292-9181

Frequently asked questions about Edgeworth Boro Muni Auth

Is Edgeworth Boro Muni Auth tap water safe to drink?

EPA monitoring detected 10 contaminants in Edgeworth Boro Muni Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Edgeworth Boro Muni Auth's water?

EPA monitoring detected Copper, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, TTHM, and others. The full list with the level and data source for each is above.

How many people does Edgeworth Boro Muni Auth serve?

Edgeworth Boro Muni Auth reports serving 7,781 people in Pennsylvania, per its EPA record.

Has Edgeworth Boro Muni Auth had any water quality violations?

The EPA has 22 violations on file for Edgeworth Boro Muni Auth, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.