← Pennsylvania

Tap water quality report

Greater Johnstown Wa Saltlick

EPA monitoring tested this supplier for 78 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
15
detected
170
people served
40
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Cambria

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

40
health-based violations
228
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
80.24 µg/L 134%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 209 µg/L
33/33 SYR4 2012–2019
Bromodichloromethane
9.9085 µg/L
No EPA limit set
worst single sample: 10.6 µg/L
32/32 SYR4 2012–2019
Chloroform
86.62 µg/L
No EPA limit set
worst single sample: 97.8 µg/L
32/32 SYR4 2012–2019
TTHM
96.315 µg/L 120%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 106 µg/L
32/32 SYR4 2012–2019
Copper
470.5 µg/L 36%
of the EPA limit 1300 µg/L
worst single sample: 480 µg/L
20/20 SYR4 2013–2019
Dibromochloromethane
1.385 µg/L
No EPA limit set
worst single sample: 1.46 µg/L
11/32 SYR4 2012–2019
Barium
49.95 µg/L 2.5%
of the EPA limit 2000 µg/L
worst single sample: 51 µg/L
8/8 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
8/8 LCR 2010
Dichloroacetic Acid
77.33 µg/L
No EPA limit set
worst single sample: 95.9 µg/L
7/7 SYR4 2015–2019
Trichloroacetic Acid
96.44 µg/L
No EPA limit set
worst single sample: 113 µg/L
7/7 SYR4 2015–2019
Fluoride
724.2 µg/L 18%
of the EPA limit 4000 µg/L
worst single sample: 728 µg/L
5/8 SYR4 2012–2019
Monochloroacetic Acid
39.1 µg/L
No EPA limit set
worst single sample: 41 µg/L
3/7 SYR4 2015–2019
Nitrate
2700 µg/L 27%
of the EPA limit 10000 µg/L
2/16 SYR4 2012–2019
Dibromoacetic Acid
0.2700 µg/L
No EPA limit set
1/7 SYR4 2015–2019
Mercury
0.2100 µg/L 11%
of the EPA limit 2 µg/L
1/8 SYR4 2012–2019
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MICHAEL KERR
Phone
814-689-4130

Frequently asked questions about Greater Johnstown Wa Saltlick

Is Greater Johnstown Wa Saltlick tap water safe to drink?

EPA monitoring detected 15 contaminants in Greater Johnstown Wa Saltlick's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greater Johnstown Wa Saltlick's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, TTHM, Copper, and others. The full list with the level and data source for each is above.

How many people does Greater Johnstown Wa Saltlick serve?

Greater Johnstown Wa Saltlick reports serving 170 people in Pennsylvania, per its EPA record.

Has Greater Johnstown Wa Saltlick had any water quality violations?

The EPA has 228 violations on file for Greater Johnstown Wa Saltlick, of which 40 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.