Tap water quality report

Blair Twp Water & Sewer Auth

EPA monitoring tested this supplier for 14 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
10
detected
2,550
people served
3
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Blair

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
41
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2017-10-01 → 2017-10-31
TT Health-based Resolved 2017-10-01 → 2017-10-31
TT Health-based Resolved 2017-10-01 → 2017-10-31
MR Monitoring Resolved 2020-07-01 → 2020-09-30
MR Monitoring Resolved 2020-07-01 → 2020-09-30
MR Monitoring Resolved 2020-07-01 → 2020-09-30
MR Monitoring Resolved 2020-07-01 → 2020-09-30
MR Monitoring Resolved 2020-07-01 → 2020-09-30
MR Monitoring Resolved 2020-07-01 → 2020-09-30
RPT Monitoring Resolved 2019-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
71.7 µg/L 5.5%
of the EPA limit 1300 µg/L
31/35 SYR4 2013–2019
Bromodichloromethane
7.53 µg/L
No EPA limit set
8/8 SYR4 2012–2019
Chloroform
30.8 µg/L
No EPA limit set
8/8 SYR4 2012–2019
Dibromochloromethane
1.82 µg/L
No EPA limit set
8/8 SYR4 2012–2019
Lead
25.5 µg/L 170%
of the EPA limit, in the worst sample — 15 µg/L
8/35 SYR4 2013–2019
TTHM
40 µg/L 50%
of the EPA limit 80 µg/L
8/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
11.9 µg/L 20%
of the EPA limit 60 µg/L
8/8 SYR4 2012–2019
Dichloroacetic Acid
9.72 µg/L
No EPA limit set
6/6 SYR4 2014–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
4/4 LCR 1996
Trichloroacetic Acid
2.56 µg/L
No EPA limit set
4/6 SYR4 2014–2019
4 contaminants tested, none detected
BromoformDibromoacetic AcidMonobromoacetic AcidMonochloroacetic Acid

Utility contact

Contact
TED VENTRE
Phone
814-695-6300

Frequently asked questions about Blair Twp Water & Sewer Auth

Is Blair Twp Water & Sewer Auth tap water safe to drink?

EPA monitoring detected 10 contaminants in Blair Twp Water & Sewer Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Blair Twp Water & Sewer Auth's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does Blair Twp Water & Sewer Auth serve?

Blair Twp Water & Sewer Auth reports serving 2,550 people in Pennsylvania, per its EPA record.

Has Blair Twp Water & Sewer Auth had any water quality violations?

The EPA has 41 violations on file for Blair Twp Water & Sewer Auth, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.