← Pennsylvania

Tap water quality report

White Haven Center

EPA monitoring tested this supplier for 80 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
14
detected
375
people served
0
health-based violations
Water source
Ground water
Ownership
State government
Counties served
Luzerne

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
509
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2024-09-01 → 2024-09-30
MR Monitoring Resolved 2024-09-01 → 2024-09-30
MR Monitoring Resolved 2024-09-01 → 2024-09-30
Other Monitoring Resolved 2021-07-01
Other Monitoring Resolved 2021-07-01
MR Monitoring Resolved 2021-04-01 → 2021-04-30
MR Monitoring Resolved 2021-04-01 → 2021-04-30
MR Monitoring Resolved 2021-04-01 → 2021-04-30
MR Monitoring Resolved 2021-04-01 → 2021-04-30
MR Monitoring Resolved 2021-04-01 → 2021-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
561.2 µg/L 43%
of the EPA limit 1300 µg/L
worst single sample: 670 µg/L
30/30 SYR4 2013–2019
Bromoform
2.69 µg/L
No EPA limit set
worst single sample: 2.8 µg/L
23/23 SYR4 2013–2019
Dibromochloromethane
5.66 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
22/23 SYR4 2013–2019
Bromodichloromethane
4.1 µg/L
No EPA limit set
21/23 SYR4 2013–2019
Chloroform
1.8 µg/L
No EPA limit set
21/23 SYR4 2013–2019
TTHM
14 µg/L 18%
of the EPA limit 80 µg/L
17/17 SYR4 2013–2019
Nitrate
1370 µg/L 14%
of the EPA limit 10000 µg/L
12/16 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
3.933 µg/L 6.6%
of the EPA limit 60 µg/L
worst single sample: 5 µg/L
12/16 SYR4 2013–2019
Lead
4.1 µg/L 27%
of the EPA limit 15 µg/L
worst single sample: 5 µg/L
10/30 SYR4 2013–2019
Xylenes, Total
7.15 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 7.8 µg/L
6/8 SYR4 2012–2019
Ethylbenzene
1.5 µg/L 0.2%
of the EPA limit 700 µg/L
worst single sample: 1.6 µg/L
5/8 SYR4 2012–2019
Lead
0.0060 mg/L 40%
of the EPA limit 0.0150 mg/L
5/5 LCR 1996
Barium
7.1 µg/L 0.4%
of the EPA limit 2000 µg/L
1/3 SYR4 2012–2018
Thallium, Total
2 µg/L 100%
of the EPA limit 2 µg/L
1/3 SYR4 2012–2018
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Gerald Goessel
Phone
570-443-4100

Frequently asked questions about White Haven Center

Is White Haven Center tap water safe to drink?

EPA monitoring detected 14 contaminants in White Haven Center's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in White Haven Center's water?

EPA monitoring detected Copper, Bromoform, Dibromochloromethane, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does White Haven Center serve?

White Haven Center reports serving 375 people in Pennsylvania, per its EPA record.

Has White Haven Center had any water quality violations?

The EPA has 509 violations on file for White Haven Center, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.