← Pennsylvania

Tap water quality report

Aqua Pa White Haven

EPA monitoring tested this supplier for 80 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
17
detected
1,200
people served
10
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Luzerne

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
75
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1993-01-01 → 1993-03-31
MCL Health-based Resolved 1992-10-01 → 1992-12-31
MCL Health-based Resolved 1992-10-01 → 1992-12-31
MCL Health-based Resolved 1992-10-01 → 1992-12-31
MCL Health-based Resolved 1992-10-01 → 1992-12-31
MCL Health-based Resolved 1992-10-01 → 1992-12-31
MCL Health-based Archived 1992-07-01 → 1992-09-30
MCL Health-based Archived 1992-07-01 → 1992-09-30
MCL Health-based Resolved 1992-04-01 → 1992-06-30
MCL Health-based Resolved 1992-04-01 → 1992-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
127.5 µg/L 9.8%
of the EPA limit 1300 µg/L
worst single sample: 150 µg/L
26/30 SYR4 2013–2019
Chloroform
6.6 µg/L
No EPA limit set
8/8 SYR4 2014–2019
TTHM
15.815 µg/L 20%
of the EPA limit 80 µg/L
worst single sample: 18.3 µg/L
8/8 SYR4 2012–2019
Nitrate
1100 µg/L 11%
of the EPA limit 10000 µg/L
6/16 SYR4 2012–2019
Bromodichloromethane
5.26 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
5/5 SYR4 2014–2019
Bromoform
1.56 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
5/5 SYR4 2014–2019
Dibromochloromethane
4.2 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
5/5 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
3.3 µg/L 5.5%
of the EPA limit 60 µg/L
5/8 SYR4 2012–2019
Lead
0.0060 mg/L 40%
of the EPA limit 0.0150 mg/L
4/4 LCR 1996
Barium
18.9 µg/L 0.9%
of the EPA limit 2000 µg/L
worst single sample: 19 µg/L
3/3 SYR4 2012–2018
Chromium
3.5 µg/L 3.5%
of the EPA limit 100 µg/L
worst single sample: 3.7 µg/L
3/3 SYR4 2012–2018
Dibromoacetic Acid
1.55 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
3/3 SYR4 2017–2019
Dichloroacetic Acid
1.66 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
3/3 SYR4 2017–2019
Toluene
0.9900 µg/L 0.1%
of the EPA limit 1000 µg/L
worst single sample: 1 µg/L
2/8 SYR4 2012–2019
Xylenes, Total
1.93 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 2 µg/L
2/8 SYR4 2012–2019
Dichloromethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/8 SYR4 2012–2019
Ethylbenzene
0.6000 µg/L 0.1%
of the EPA limit 700 µg/L
1/8 SYR4 2012–2019
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DAVID HOOGSTAD
Phone
570-443-7099

Frequently asked questions about Aqua Pa White Haven

Is Aqua Pa White Haven tap water safe to drink?

EPA monitoring detected 17 contaminants in Aqua Pa White Haven's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Aqua Pa White Haven's water?

EPA monitoring detected Copper, Chloroform, TTHM, Nitrate, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Aqua Pa White Haven serve?

Aqua Pa White Haven reports serving 1,200 people in Pennsylvania, per its EPA record.

Has Aqua Pa White Haven had any water quality violations?

The EPA has 75 violations on file for Aqua Pa White Haven, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.