Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Resolved | 2023-07-01 |
| Other | Monitoring | Resolved | 2023-07-01 |
| Other | Monitoring | Resolved | 2001-07-01 → 2001-08-13 |
| MR | Monitoring | Resolved | 1997-04-01 → 1997-06-30 |
| MR | Monitoring | Resolved | 1997-01-01 → 1997-03-31 |
| MR | Monitoring | Resolved | 1997-01-01 → 1997-03-31 |
| MR | Monitoring | Resolved | 1996-01-01 → 1996-12-31 |
| MR | Monitoring | Resolved | 1996-01-01 → 1996-12-31 |
| MR | Monitoring | Resolved | 1996-01-01 → 1996-12-31 |
| MR | Monitoring | Resolved | 1996-01-01 → 1996-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1600 µg/L 123% of the EPA limit, in the worst sample — 1300 µg/L | 33/33 | SYR4 | 2013–2019 |
| Nitrate | 4400 µg/L 44% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| TTHM | 10.5 µg/L 13% of the EPA limit 80 µg/L | 7/8 | SYR4 | 2013–2019 |
| Chloroform | 4.8 µg/L No EPA limit set | 6/6 | SYR4 | 2017–2019 |
| Lead | 20 µg/L 133% of the EPA limit, in the worst sample — 15 µg/L | 6/33 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 4.7 µg/L 7.8% of the EPA limit 60 µg/L | 5/8 | SYR4 | 2013–2019 |
| Barium | 786 µg/L 39% of the EPA limit 2000 µg/L | 3/3 | SYR4 | 2012–2018 |
| Bromodichloromethane | 2.6 µg/L No EPA limit set | 3/3 | SYR4 | 2017–2019 |
| Bromoform | 0.8000 µg/L No EPA limit set | 3/3 | SYR4 | 2017–2019 |
| Chromium | 4.1 µg/L 4.1% of the EPA limit 100 µg/L | 3/3 | SYR4 | 2012–2018 |
| Dibromochloromethane | 2.3 µg/L No EPA limit set | 3/3 | SYR4 | 2017–2019 |
| Combined Uranium | 1.39762 µg/L 4.7% of the EPA limit 30 µg/L | 2/2 | SYR4 | 2012–2018 |
| Dibromoacetic Acid | 1.4 µg/L No EPA limit set | 2/3 | SYR4 | 2017–2019 |
| Dichloroacetic Acid | 2 µg/L No EPA limit set | 2/3 | SYR4 | 2017–2019 |
| Lead | 0.0020 mg/L 13% of the EPA limit 0.0150 mg/L | 2/2 | LCR | 1994 |
| Arsenic | 2.4 µg/L 24% of the EPA limit 10 µg/L | 1/3 | SYR4 | 2012–2018 |
| Selenium | 1 µg/L 2% of the EPA limit 50 µg/L | 1/3 | SYR4 | 2012–2018 |
32 contaminants tested, none detected
Utility contact
Frequently asked questions about Aqua Pa Perkiomen Woods
Is Aqua Pa Perkiomen Woods tap water safe to drink?
EPA monitoring detected 17 contaminants in Aqua Pa Perkiomen Woods's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Aqua Pa Perkiomen Woods's water?
EPA monitoring detected Copper, Nitrate, TTHM, Chloroform, Lead, and others. The full list with the level and data source for each is above.
How many people does Aqua Pa Perkiomen Woods serve?
Aqua Pa Perkiomen Woods reports serving 1,100 people in Pennsylvania, per its EPA record.
Has Aqua Pa Perkiomen Woods had any water quality violations?
The EPA has 34 violations on file for Aqua Pa Perkiomen Woods, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.