← Oklahoma

Tap water quality report

Carriage Hills

EPA monitoring tested this supplier for 50 contaminants and detected 7. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

50
contaminants tested
7
detected
160
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Delaware

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
75
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MR Monitoring Unaddressed 2026-01-01
MR Monitoring Unaddressed 2026-01-01
Other Monitoring Unaddressed 2025-07-01
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
MR Monitoring Resolved 2024-10-01
MR Monitoring Resolved 2024-10-01
MR Monitoring Resolved 2024-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0026 mg/L 17%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Combined Radium (-226 And -228)
2.28 pCi/L 46%
of the EPA limit 5 pCi/L
5/5 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
4.09 pCi/L 27%
of the EPA limit 15 pCi/L
4/5 SYR4 2013–2019
Gross Beta Particle Activity
5.48 pCi/L
No EPA limit set
4/5 SYR4 2013–2019
Copper
112 µg/L 8.6%
of the EPA limit 1300 µg/L
2/15 SYR4 2012–2018
Barium
78.1 µg/L 3.9%
of the EPA limit 2000 µg/L
1/1 SYR4 2017
Fluoride
2760 µg/L 69%
of the EPA limit 4000 µg/L
1/1 SYR4 2017
43 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBenzeneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCadmiumCarbon TetrachlorideChloroformChromiumCombined UraniumDichloromethaneDibromoacetic AcidDibromochloromethaneDichloroacetic AcidEthylbenzeneLeadMercuryMonobromoacetic AcidMonochloroacetic AcidNitrate-NitriteSeleniumStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Trichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CARRIAGE HILLS
Phone
918-257-0892
Email
alan_dianasmith@yahoo.com

Frequently asked questions about Carriage Hills

Is Carriage Hills tap water safe to drink?

EPA monitoring detected 7 contaminants in Carriage Hills's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Carriage Hills's water?

EPA monitoring detected Lead, Combined Radium (-226 And -228), Gross Alpha, Excl. Radon And U, Gross Beta Particle Activity, Copper, and others. The full list with the level and data source for each is above.

How many people does Carriage Hills serve?

Carriage Hills reports serving 160 people in Oklahoma, per its EPA record.

Has Carriage Hills had any water quality violations?

The EPA has 75 violations on file for Carriage Hills, of which 2 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.