← Oklahoma

Tap water quality report

Carriage Village

EPA monitoring tested this supplier for 14 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
12
detected
500
people served
2
health-based violations
Water source
SWP
Ownership
Private
Counties served
Tulsa

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
63
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2022-10-02
Other Monitoring Resolved 2022-10-02
MR Monitoring Resolved 2021-10-01
MR Monitoring Resolved 2021-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
42.2 µg/L 3.2%
of the EPA limit 1300 µg/L
worst single sample: 86 µg/L
33/49 SYR4 2012–2018
Bromodichloromethane
13.68 µg/L
No EPA limit set
worst single sample: 14.1 µg/L
13/13 SYR4 2014–2019
Chloroform
33.4 µg/L
No EPA limit set
worst single sample: 38.8 µg/L
13/13 SYR4 2014–2019
Dibromochloromethane
8.254 µg/L
No EPA limit set
worst single sample: 8.38 µg/L
13/13 SYR4 2014–2019
Dichloroacetic Acid
10.92 µg/L
No EPA limit set
worst single sample: 11.4 µg/L
13/13 SYR4 2014–2019
TTHM
49.62 µg/L 62%
of the EPA limit 80 µg/L
worst single sample: 54 µg/L
13/13 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
20.76 µg/L 35%
of the EPA limit 60 µg/L
worst single sample: 21.6 µg/L
13/13 SYR4 2014–2019
Trichloroacetic Acid
8.71 µg/L
No EPA limit set
worst single sample: 10.3 µg/L
13/13 SYR4 2014–2019
Dibromoacetic Acid
1.874 µg/L
No EPA limit set
worst single sample: 2 µg/L
8/13 SYR4 2014–2019
Lead
0.00070 mg/L 4.7%
of the EPA limit 0.0150 mg/L
6/6 LCR 2024
Bromoform
1.0765 µg/L
No EPA limit set
worst single sample: 1.08 µg/L
2/13 SYR4 2014–2019
Lead
18.055 µg/L 120%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 18.5 µg/L
2/49 SYR4 2012–2018
2 contaminants tested, none detected
Monobromoacetic AcidMonochloroacetic Acid

Utility contact

Contact
CARRIAGE VILLAGE
Phone
918-838-7857
Email
carriagevillage@westwindenterprises.com

Frequently asked questions about Carriage Village

Is Carriage Village tap water safe to drink?

EPA monitoring detected 12 contaminants in Carriage Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Carriage Village's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Carriage Village serve?

Carriage Village reports serving 500 people in Oklahoma, per its EPA record.

Has Carriage Village had any water quality violations?

The EPA has 63 violations on file for Carriage Village, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.