← Oklahoma

Tap water quality report

Tryon

EPA monitoring tested this supplier for 50 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

50
contaminants tested
13
detected
448
people served
88
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Lincoln

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

88
health-based violations
631
violations on file
20
still open
ViolationTypeStatusPeriod
TT Health-based Addressed 2024-10-17
TT Health-based Addressed 2024-10-17
MRDL Health-based Resolved 2021-10-01 → 2021-10-31
MRDL Health-based Resolved 2021-10-01 → 2021-10-31
MRDL Health-based Resolved 2021-10-01 → 2021-10-31
MRDL Health-based Resolved 2021-10-01 → 2021-10-31
MRDL Health-based Resolved 2021-04-01 → 2021-06-30
MRDL Health-based Resolved 2021-04-01 → 2021-06-30
MRDL Health-based Resolved 2021-04-01 → 2021-06-30
MRDL Health-based Resolved 2021-04-01 → 2021-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
614 µg/L 6.1%
of the EPA limit 10000 µg/L
worst single sample: 640 µg/L
34/38 SYR4 2012–2019
Combined Uranium
32.325 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 55.1 µg/L
32/32 SYR4 2013–2019
Gross Beta Particle Activity
11.5 pCi/L
No EPA limit set
worst single sample: 12.6 pCi/L
31/32 SYR4 2013–2019
Combined Radium (-226 And -228)
2.312 pCi/L 46%
of the EPA limit 5 pCi/L
worst single sample: 3.16 pCi/L
29/32 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
23.639 pCi/L 158%
of the EPA limit, at the 95th percentile of samples — 15 pCi/L
worst single sample: 71.8 pCi/L
27/32 SYR4 2013–2019
Copper
152.7 µg/L 12%
of the EPA limit 1300 µg/L
worst single sample: 384 µg/L
19/22 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
Barium
260.75 µg/L 13%
of the EPA limit 2000 µg/L
worst single sample: 261 µg/L
2/2 SYR4 2014
Chloroform
1.7635 µg/L
No EPA limit set
worst single sample: 1.77 µg/L
2/7 SYR4 2013–2019
Fluoride
300 µg/L 7.5%
of the EPA limit 4000 µg/L
2/2 SYR4 2014
Selenium
11.68 µg/L 23%
of the EPA limit 50 µg/L
worst single sample: 11.7 µg/L
2/2 SYR4 2014
Bromodichloromethane
1.09 µg/L
No EPA limit set
1/7 SYR4 2013–2019
TTHM
2.73 µg/L 3.4%
of the EPA limit 80 µg/L
1/5 SYR4 2013–2019
37 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBenzeneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbon TetrachlorideChromiumDichloromethaneDibromoacetic AcidDibromochloromethaneDichloroacetic AcidEthylbenzeneLeadMercuryMonobromoacetic AcidMonochloroacetic AcidStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Trichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TRYON
Phone
918-374-2227
Email
townoftryon74875@gmail.com

Frequently asked questions about Tryon

Is Tryon tap water safe to drink?

EPA monitoring detected 13 contaminants in Tryon's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Tryon's water?

EPA monitoring detected Nitrate-Nitrite, Combined Uranium, Gross Beta Particle Activity, Combined Radium (-226 And -228), Gross Alpha, Excl. Radon And U, and others. The full list with the level and data source for each is above.

How many people does Tryon serve?

Tryon reports serving 448 people in Oklahoma, per its EPA record.

Has Tryon had any water quality violations?

The EPA has 631 violations on file for Tryon, of which 88 are health-based (a contaminant limit or required treatment was breached) and 20 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.