← Oklahoma

Tap water quality report

Okarche Rwd, Inc

EPA monitoring tested this supplier for 55 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

55
contaminants tested
13
detected
250
people served
919
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Kingfisher

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

919
health-based violations
1,103
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
2540 µg/L 195%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 4280 µg/L
76/80 SYR4 2012–2017
Nitrate-Nitrite
17890 µg/L 179%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 18100 µg/L
32/32 SYR4 2012–2019
Lead
0.0041 mg/L 27%
of the EPA limit 0.0150 mg/L
18/18 LCR 2023
Bromoform
15.91 µg/L
No EPA limit set
worst single sample: 16.3 µg/L
14/16 SYR4 2012–2019
Dibromochloromethane
3.2 µg/L
No EPA limit set
14/16 SYR4 2012–2019
TTHM
19.285 µg/L 24%
of the EPA limit 80 µg/L
worst single sample: 20 µg/L
14/14 SYR4 2012–2019
Vinyl Chloride
20.75 µg/L 1038%
of the EPA limit, at the 95th percentile of samples — 2 µg/L
worst single sample: 25.8 µg/L
11/85 SYR4 2012–2017
Dibromoacetic Acid
3.21 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
4/4 SYR4 2012–2019
Nitrate
18000 µg/L 180%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
4/4 SYR4 2012–2018
Arsenic
6.585 µg/L 66%
of the EPA limit 10 µg/L
worst single sample: 6.8 µg/L
2/2 SYR4 2012–2016
Total Haloacetic Acids (HAA5)
2.39 µg/L 4%
of the EPA limit 60 µg/L
worst single sample: 2.4 µg/L
2/4 SYR4 2012–2019
Barium
162 µg/L 8.1%
of the EPA limit 2000 µg/L
1/1 SYR4 2017
Bromodichloromethane
0.5000 µg/L
No EPA limit set
1/16 SYR4 2012–2019
42 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChloroformChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDichloroacetic AcidEthylene DibromideEthylbenzeneFluorideGross Alpha, Excl. Radon And UGross Beta Particle ActivityLeadMercuryMonobromoacetic AcidMonochloroacetic AcidNitriteSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
OKARCHE RWD, INC
Phone
405-263-4835
Email
okarcheruralwater@gmail.com

Frequently asked questions about Okarche Rwd, Inc

Is Okarche Rwd, Inc tap water safe to drink?

EPA monitoring detected 13 contaminants in Okarche Rwd, Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Okarche Rwd, Inc's water?

EPA monitoring detected Copper, Nitrate-Nitrite, Lead, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Okarche Rwd, Inc serve?

Okarche Rwd, Inc reports serving 250 people in Oklahoma, per its EPA record.

Has Okarche Rwd, Inc had any water quality violations?

The EPA has 1103 violations on file for Okarche Rwd, Inc, of which 919 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.