← Ohio

Tap water quality report

Scioto Water Inc. - Zeigler Lane

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
76
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Scioto

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
8
violations on file
1
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2025-07-02
RPT Monitoring Resolved 2025-07-02
RPT Monitoring Resolved 2025-07-02
Other Monitoring Unaddressed 2020-02-04
MR Monitoring Resolved 1994-12-01 → 1994-12-31
MR Monitoring Resolved 1994-12-01 → 1994-12-31
MR Monitoring Resolved 1994-12-01 → 1994-12-31
MR Monitoring Resolved 1994-12-01 → 1994-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
34.6 µg/L
No EPA limit set
30/30 SYR4 2012–2019
Chloroform
60.8 µg/L
No EPA limit set
30/30 SYR4 2012–2019
Dibromochloromethane
30.9 µg/L
No EPA limit set
30/30 SYR4 2012–2019
TTHM
99.3 µg/L 124%
of the EPA limit, in the worst sample — 80 µg/L
30/30 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
34 µg/L 57%
of the EPA limit 60 µg/L
30/30 SYR4 2012–2019
Dichloroacetic Acid
15.5 µg/L
No EPA limit set
29/30 SYR4 2012–2019
Trichloroacetic Acid
23.6 µg/L
No EPA limit set
29/30 SYR4 2012–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Dibromoacetic Acid
15.5 µg/L
No EPA limit set
15/30 SYR4 2012–2019
Bromoform
6.3 µg/L
No EPA limit set
12/30 SYR4 2012–2019
Copper
99 µg/L 7.6%
of the EPA limit 1300 µg/L
4/15 SYR4 2012–2018
Lead
8.7 µg/L 58%
of the EPA limit 15 µg/L
2/15 SYR4 2012–2018
Monobromoacetic Acid
1 µg/L
No EPA limit set
1/30 SYR4 2012–2019
Monochloroacetic Acid
2 µg/L
No EPA limit set
1/30 SYR4 2012–2019

Utility contact

Contact
SPRADLIN, JEFF
Phone
740-354-9140
Email
sciotowatergm@aol.com

Frequently asked questions about Scioto Water Inc. - Zeigler Lane

Is Scioto Water Inc. - Zeigler Lane tap water safe to drink?

EPA monitoring detected 14 contaminants in Scioto Water Inc. - Zeigler Lane's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Scioto Water Inc. - Zeigler Lane's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Scioto Water Inc. - Zeigler Lane serve?

Scioto Water Inc. - Zeigler Lane reports serving 76 people in Ohio, per its EPA record.

Has Scioto Water Inc. - Zeigler Lane had any water quality violations?

The EPA has 8 violations on file for Scioto Water Inc. - Zeigler Lane, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.