Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
| MR | Monitoring | Resolved | 1986-08-28 → 1989-08-27 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfpea | 0.0031 µg/L | 1/4 | 2025 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1340 µg/L 103% of the EPA limit, in the worst sample — 1300 µg/L | 114/120 | SYR4 | 2013–2019 |
| Bromodichloromethane | 12.9 µg/L No EPA limit set | 38/38 | SYR4 | 2012–2019 |
| Chloroform | 15.2 µg/L No EPA limit set | 38/38 | SYR4 | 2012–2019 |
| Dibromochloromethane | 8.7 µg/L No EPA limit set | 38/38 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 11.3 µg/L No EPA limit set | 38/38 | SYR4 | 2012–2019 |
| TTHM | 37.2 µg/L 47% of the EPA limit 80 µg/L | 38/38 | SYR4 | 2012–2019 |
| Bromoform | 1.69 µg/L No EPA limit set | 33/38 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 2.8 µg/L No EPA limit set | 32/38 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 5.5 µg/L No EPA limit set | 31/38 | SYR4 | 2012–2019 |
| Nitrate | 2100 µg/L 21% of the EPA limit 10000 µg/L | 28/32 | SYR4 | 2012–2019 |
| Lead | 0.0018 mg/L 12% of the EPA limit 0.0150 mg/L | 22/22 | LCR | 2025 |
| Total Haloacetic Acids (HAA5) | 16.8 µg/L 28% of the EPA limit 60 µg/L | 20/38 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 2100 µg/L 21% of the EPA limit 10000 µg/L | 14/16 | SYR4 | 2012–2019 |
| Barium | 47.5 µg/L 2.4% of the EPA limit 2000 µg/L | 6/6 | SYR4 | 2013–2019 |
| Fluoride | 1080 µg/L 27% of the EPA limit 4000 µg/L | 6/6 | SYR4 | 2013–2019 |
| Lead | 5.6 µg/L 37% of the EPA limit 15 µg/L | 1/120 | SYR4 | 2013–2019 |
66 contaminants tested, none detected
Utility contact
Frequently asked questions about Ross County Water Co Inc
Is Ross County Water Co Inc tap water safe to drink?
EPA monitoring detected 17 contaminants in Ross County Water Co Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Ross County Water Co Inc's water?
EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Ross County Water Co Inc serve?
Ross County Water Co Inc reports serving 35,345 people in Ohio, per its EPA record.
Has Ross County Water Co Inc had any water quality violations?
The EPA has 24 violations on file for Ross County Water Co Inc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.