← New York

Tap water quality report

796 Bedford Road Apartments

EPA monitoring tested this supplier for 75 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
16
detected
40
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Westchester

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
154
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-01-01 → 2016-12-31
MCL Health-based Resolved 2014-01-01 → 2016-12-31
MCL Health-based Resolved 2014-01-01 → 2016-12-31
MCL Health-based Resolved 2014-01-01 → 2016-12-31
MON Monitoring Archived 2018-11-01 → 2018-11-30
MON Monitoring Archived 2018-11-01 → 2018-11-30
MR Monitoring Resolved 2012-02-01 → 2012-02-29
MR Monitoring Resolved 2012-02-01 → 2012-02-29
MR Monitoring Resolved 2012-02-01 → 2012-02-29
MR Monitoring Resolved 2012-02-01 → 2012-02-29

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
250 µg/L 2.5%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Lead
0.0013 mg/L 8.9%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Nitrate-Nitrite
236 µg/L 2.4%
of the EPA limit 10000 µg/L
worst single sample: 250 µg/L
8/9 SYR4 2012–2019
TTHM
2.85 µg/L 3.6%
of the EPA limit 80 µg/L
worst single sample: 3 µg/L
6/14 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
5.3 µg/L 88%
of the EPA limit 6 µg/L
worst single sample: 5.8 µg/L
5/8 SYR4 2013–2019
Bromoform
0.8390 µg/L
No EPA limit set
worst single sample: 0.8400 µg/L
3/12 SYR4 2012–2019
Combined Radium (-226 And -228)
2.6905 pCi/L 54%
of the EPA limit 5 pCi/L
worst single sample: 2.76 pCi/L
3/3 SYR4 2017–2019
Combined Uranium
1.5124 µg/L 5%
of the EPA limit 30 µg/L
worst single sample: 1.63 µg/L
3/3 SYR4 2017–2019
Gross Alpha, Excl. Radon And U
2.923 pCi/L 19%
of the EPA limit 15 pCi/L
worst single sample: 2.97 pCi/L
3/3 SYR4 2017–2019
Barium
34 µg/L 1.7%
of the EPA limit 2000 µg/L
2/2 SYR4 2014–2017
Bromodichloromethane
0.8640 µg/L
No EPA limit set
worst single sample: 0.8700 µg/L
2/12 SYR4 2012–2019
Chloroform
1.0855 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
2/12 SYR4 2012–2019
Dibromochloromethane
0.6960 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
2/12 SYR4 2012–2019
Nitrite
10 µg/L 1%
of the EPA limit 1000 µg/L
2/9 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
1 µg/L 1.7%
of the EPA limit 60 µg/L
2/14 SYR4 2012–2019
Gross Beta Particle Activity
8.37 pCi/L
No EPA limit set
1/1 SYR4 2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RODRIGUES, ANTONIO
Phone
914-424-9969
Email
none

Frequently asked questions about 796 Bedford Road Apartments

Is 796 Bedford Road Apartments tap water safe to drink?

EPA monitoring detected 16 contaminants in 796 Bedford Road Apartments's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in 796 Bedford Road Apartments's water?

EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, TTHM, Di(2-ethylhexyl) Phthalate, and others. The full list with the level and data source for each is above.

How many people does 796 Bedford Road Apartments serve?

796 Bedford Road Apartments reports serving 40 people in New York, per its EPA record.

Has 796 Bedford Road Apartments had any water quality violations?

The EPA has 154 violations on file for 796 Bedford Road Apartments, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.