← New York

Tap water quality report

Potsdam Village

EPA monitoring tested this supplier for 100 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

100
contaminants tested
15
detected
8,312
people served
48
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
St. Lawrence

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

48
health-based violations
190
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
94.2 µg/L
No EPA limit set
worst single sample: 116 µg/L
57/57 SYR4 2012–2019
TTHM
97.2 µg/L 122%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 119 µg/L
57/57 SYR4 2012–2019
Bromodichloromethane
3 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
56/57 SYR4 2012–2019
Dichloroacetic Acid
35.5 µg/L
No EPA limit set
worst single sample: 42 µg/L
56/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
79 µg/L 132%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 112 µg/L
55/56 SYR4 2012–2019
Trichloroacetic Acid
46.6 µg/L
No EPA limit set
worst single sample: 70 µg/L
53/57 SYR4 2012–2019
Fluoride
700 µg/L 18%
of the EPA limit 4000 µg/L
worst single sample: 840 µg/L
37/40 SYR4 2012–2019
Nitrate
260 µg/L 2.6%
of the EPA limit 10000 µg/L
14/16 SYR4 2012–2019
Lead
0.0078 mg/L 52%
of the EPA limit 0.0150 mg/L
13/13 LCR 2024
Barium
11.5 µg/L 0.6%
of the EPA limit 2000 µg/L
worst single sample: 12 µg/L
6/8 SYR4 2012–2019
Monochloroacetic Acid
2.175 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
6/57 SYR4 2012–2019
Monobromoacetic Acid
7.68 µg/L
No EPA limit set
worst single sample: 7.8 µg/L
3/57 SYR4 2012–2019
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Dibromoacetic Acid
1.9 µg/L
No EPA limit set
1/57 SYR4 2012–2019
Dibromochloromethane
0.6400 µg/L
No EPA limit set
1/57 SYR4 2012–2019
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
POTSDAM MAYOR & VILLAGE BOARD
Phone
315-265-7480
Email
mayor@vi.potsdam.ny.us

Frequently asked questions about Potsdam Village

Is Potsdam Village tap water safe to drink?

EPA monitoring detected 15 contaminants in Potsdam Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Potsdam Village's water?

EPA monitoring detected Chloroform, TTHM, Bromodichloromethane, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Potsdam Village serve?

Potsdam Village reports serving 8,312 people in New York, per its EPA record.

Has Potsdam Village had any water quality violations?

The EPA has 190 violations on file for Potsdam Village, of which 48 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.