← New York

Tap water quality report

Goshen W.D. #2 (Arcadia Hills)

EPA monitoring tested this supplier for 63 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

63
contaminants tested
13
detected
822
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Orange

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
356
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2024-10-17
MR Monitoring Resolved 2006-10-01
MR Monitoring Resolved 2006-10-01
MR Monitoring Resolved 2006-10-01
MR Monitoring Resolved 2006-10-01
MR Monitoring Resolved 2006-01-01 → 2008-12-31
MR Monitoring Resolved 2006-01-01 → 2008-12-31
MR Monitoring Resolved 2006-01-01 → 2008-12-31
MR Monitoring Resolved 2006-01-01 → 2008-12-31
MR Monitoring Resolved 2006-01-01 → 2008-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
655 µg/L 6.6%
of the EPA limit 10000 µg/L
18/56 SYR4 2012–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Barium
124 µg/L 6.2%
of the EPA limit 2000 µg/L
12/12 SYR4 2013–2019
TTHM
14 µg/L 18%
of the EPA limit 80 µg/L
8/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
3.6 µg/L 6%
of the EPA limit 60 µg/L
8/10 SYR4 2013–2019
Arsenic
2.64 µg/L 26%
of the EPA limit 10 µg/L
5/13 SYR4 2013–2019
Chromium
19.1 µg/L 19%
of the EPA limit 100 µg/L
4/13 SYR4 2013–2019
Selenium
8.1 µg/L 16%
of the EPA limit 50 µg/L
3/13 SYR4 2013–2019
Combined Radium (-226 And -228)
1.64 pCi/L 33%
of the EPA limit 5 pCi/L
2/5 SYR4 2013–2019
Combined Uranium
2.3989 µg/L 8%
of the EPA limit 30 µg/L
2/3 SYR4 2014
Toluene
65.3 µg/L 6.5%
of the EPA limit 1000 µg/L
2/6 SYR4 2015
Antimony, Total
0.4210 µg/L 7%
of the EPA limit 6 µg/L
1/13 SYR4 2013–2019
Fluoride
205 µg/L 5.1%
of the EPA limit 4000 µg/L
1/13 SYR4 2013–2019
50 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GOSHEN, SUPERVISOR & TOWN BD
Phone
845-294-6033
Email
karina@townofgoshen.org

Frequently asked questions about Goshen W.D. #2 (Arcadia Hills)

Is Goshen W.D. #2 (Arcadia Hills) tap water safe to drink?

EPA monitoring detected 13 contaminants in Goshen W.D. #2 (Arcadia Hills)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Goshen W.D. #2 (Arcadia Hills)'s water?

EPA monitoring detected Nitrate, Lead, Barium, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Goshen W.D. #2 (Arcadia Hills) serve?

Goshen W.D. #2 (Arcadia Hills) reports serving 822 people in New York, per its EPA record.

Has Goshen W.D. #2 (Arcadia Hills) had any water quality violations?

The EPA has 356 violations on file for Goshen W.D. #2 (Arcadia Hills), of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.