← New York

Tap water quality report

Pine Island Water Co.

EPA monitoring tested this supplier for 66 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

66
contaminants tested
9
detected
144
people served
1
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Orange

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
21
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1995-10-01 → 1995-10-31
MR Monitoring Resolved 2015-01-01 → 2017-12-31
MR Monitoring Resolved 2015-01-01 → 2017-12-31
MR Monitoring Resolved 2015-01-01 → 2017-12-31
MR Monitoring Resolved 2015-01-01 → 2017-12-31
MR Monitoring Resolved 2015-01-01 → 2017-12-31
MR Monitoring Resolved 2015-01-01 → 2017-12-31
MR Monitoring Resolved 2009-10-01
MR Monitoring Resolved 2009-10-01
MR Monitoring Resolved 2009-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3450 µg/L 35%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0019 mg/L 13%
of the EPA limit 0.0150 mg/L
11/11 LCR 2025
TTHM
32.84 µg/L 41%
of the EPA limit 80 µg/L
worst single sample: 37.7 µg/L
5/5 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
12.8 µg/L 21%
of the EPA limit 60 µg/L
5/6 SYR4 2013–2019
Barium
131.5 µg/L 6.6%
of the EPA limit 2000 µg/L
worst single sample: 133 µg/L
3/3 SYR4 2014–2017
Combined Uranium
1.83025 µg/L 6.1%
of the EPA limit 30 µg/L
worst single sample: 1.865 µg/L
2/2 SYR4 2013–2016
Bromodichloromethane
4.3 µg/L
No EPA limit set
1/1 SYR4 2014
Bromoform
0.7000 µg/L
No EPA limit set
1/1 SYR4 2014
Chloroform
3.7 µg/L
No EPA limit set
1/1 SYR4 2014
57 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WARWICK, SUPERVISOR & TOWN BD
Phone
845-986-1120
Email
supervisor@townofwarwick.org

Frequently asked questions about Pine Island Water Co.

Is Pine Island Water Co. tap water safe to drink?

EPA monitoring detected 9 contaminants in Pine Island Water Co.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pine Island Water Co.'s water?

EPA monitoring detected Nitrate, Lead, TTHM, Total Haloacetic Acids (HAA5), Barium, and others. The full list with the level and data source for each is above.

How many people does Pine Island Water Co. serve?

Pine Island Water Co. reports serving 144 people in New York, per its EPA record.

Has Pine Island Water Co. had any water quality violations?

The EPA has 21 violations on file for Pine Island Water Co., of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.