← New York

Tap water quality report

Walters Mobile Home Village

EPA monitoring tested this supplier for 62 contaminants and detected 7. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

62
contaminants tested
7
detected
250
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Orange

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
9
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2024-10-17
Other Monitoring Resolved 2012-07-01 → 2012-07-31
Other Monitoring Resolved 2012-07-01 → 2012-07-31
Other Monitoring Resolved 2012-07-01 → 2012-07-31
Other Monitoring Resolved 2010-10-01 → 2010-10-31
Other Monitoring Resolved 2010-10-01 → 2010-10-31
Other Monitoring Resolved 2010-10-01 → 2010-10-31
MR Monitoring Resolved 1994-01-01
MR Monitoring Resolved 1993-01-01 → 1993-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2400 µg/L 24%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0026 mg/L 17%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Barium
25.4 µg/L 1.3%
of the EPA limit 2000 µg/L
3/3 SYR4 2013–2019
TTHM
5.42 µg/L 6.8%
of the EPA limit 80 µg/L
3/3 SYR4 2013–2019
Combined Radium (-226 And -228)
1 pCi/L 20%
of the EPA limit 5 pCi/L
1/1 SYR4 2014
Combined Uranium
1 µg/L 3.3%
of the EPA limit 30 µg/L
1/2 SYR4 2014
Selenium
2.63 µg/L 5.3%
of the EPA limit 50 µg/L
1/3 SYR4 2013–2019
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DANTAS, ALLEN C.
Phone
845-564-1993
Email
Dantas1a@aol.com

Frequently asked questions about Walters Mobile Home Village

Is Walters Mobile Home Village tap water safe to drink?

EPA monitoring detected 7 contaminants in Walters Mobile Home Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Walters Mobile Home Village's water?

EPA monitoring detected Nitrate, Lead, Barium, TTHM, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.

How many people does Walters Mobile Home Village serve?

Walters Mobile Home Village reports serving 250 people in New York, per its EPA record.

Has Walters Mobile Home Village had any water quality violations?

The EPA has 9 violations on file for Walters Mobile Home Village, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.