← New York

Tap water quality report

Winebrook Hills Wd

EPA monitoring tested this supplier for 71 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
18
detected
250
people served
328
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Essex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

328
health-based violations
503
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2018-01-01 → 2018-03-31
MCL Health-based Archived 2018-01-01 → 2018-03-31
MCL Health-based Archived 2018-01-01 → 2018-03-31
MCL Health-based Archived 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2016-07-01 → 2016-09-30
MCL Health-based Resolved 2016-07-01 → 2016-09-30
MCL Health-based Resolved 2016-07-01 → 2016-09-30
MCL Health-based Resolved 2016-07-01 → 2016-09-30
MCL Health-based Resolved 2016-07-01 → 2016-09-30
MCL Health-based Resolved 2016-07-01 → 2016-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
208.4 µg/L
No EPA limit set
worst single sample: 230 µg/L
29/29 SYR4 2012–2019
TTHM
210.8 µg/L 264%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 235 µg/L
29/29 SYR4 2012–2019
Bromodichloromethane
4.542 µg/L
No EPA limit set
worst single sample: 6.06 µg/L
28/29 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
197.45 µg/L 329%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 216 µg/L
27/29 SYR4 2012–2019
Dichloroacetic Acid
54.875 µg/L
No EPA limit set
worst single sample: 74 µg/L
26/29 SYR4 2012–2019
Trichloroacetic Acid
151.3 µg/L
No EPA limit set
worst single sample: 156 µg/L
23/29 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Nitrate
708 µg/L 7.1%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Dibromochloromethane
4.05 µg/L
No EPA limit set
worst single sample: 4.38 µg/L
6/29 SYR4 2012–2019
Barium
39.02 µg/L 2%
of the EPA limit 2000 µg/L
worst single sample: 40 µg/L
5/7 SYR4 2012–2018
Bromoform
1.0175 µg/L
No EPA limit set
worst single sample: 1.04 µg/L
4/29 SYR4 2012–2019
Monochloroacetic Acid
3.785 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
2/29 SYR4 2012–2019
Antimony, Total
0.3000 µg/L 5%
of the EPA limit 6 µg/L
1/7 SYR4 2012–2018
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
1/7 SYR4 2012–2018
Dibromoacetic Acid
1 µg/L
No EPA limit set
1/29 SYR4 2012–2019
Fluoride
146 µg/L 3.7%
of the EPA limit 4000 µg/L
1/7 SYR4 2012–2018
Selenium
0.5000 µg/L 1%
of the EPA limit 50 µg/L
1/7 SYR4 2012–2018
P-Dichlorobenzene
2 µg/L 2.7%
of the EPA limit 75 µg/L
1/5 SYR4 2013–2019
53 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NEWCOMB SUPERVISOR AND TOWN BOARD
Phone
518-582-3211
Email
supervisor@newcombny.com

Frequently asked questions about Winebrook Hills Wd

Is Winebrook Hills Wd tap water safe to drink?

EPA monitoring detected 18 contaminants in Winebrook Hills Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Winebrook Hills Wd's water?

EPA monitoring detected Chloroform, TTHM, Bromodichloromethane, Total Haloacetic Acids (HAA5), Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Winebrook Hills Wd serve?

Winebrook Hills Wd reports serving 250 people in New York, per its EPA record.

Has Winebrook Hills Wd had any water quality violations?

The EPA has 503 violations on file for Winebrook Hills Wd, of which 328 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.