← New York

Tap water quality report

United Wappinger Water Improvement Dist.

EPA monitoring tested this supplier for 106 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

106
contaminants tested
26
detected
14,000
people served
2
health-based violations
Water source
Ground water under surface influence
Ownership
Local government
Counties served
Dutchess

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
8
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2012-03-21
TT Health-based Resolved 2012-03-21
MR Monitoring Resolved 2014-08-01 → 2014-08-31
MR Monitoring Resolved 2014-08-01 → 2014-08-31
MR Monitoring Resolved 2007-06-01
MR Monitoring Resolved 2007-06-01
Other Monitoring Resolved 1999-10-19
Other Monitoring Resolved 1999-10-19

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0053 µg/L 1/12 2024
PFBS 0.0030 µg/L 1/12 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Dichloroacetic Acid
8.935 µg/L
No EPA limit set
worst single sample: 25 µg/L
50/50 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
15.655 µg/L 26%
of the EPA limit 60 µg/L
worst single sample: 29 µg/L
50/50 SYR4 2012–2019
Trichloroacetic Acid
4.5925 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
50/50 SYR4 2012–2019
Bromodichloromethane
13 µg/L
No EPA limit set
worst single sample: 15 µg/L
46/46 SYR4 2012–2019
Chloroform
24.75 µg/L
No EPA limit set
worst single sample: 27 µg/L
46/46 SYR4 2012–2019
Dibromochloromethane
8.75 µg/L
No EPA limit set
worst single sample: 9.8 µg/L
46/46 SYR4 2012–2019
TTHM
46 µg/L 57%
of the EPA limit 80 µg/L
worst single sample: 52 µg/L
46/46 SYR4 2012–2019
Bromoform
1.5 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
43/46 SYR4 2012–2019
Dibromoacetic Acid
2.395 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
42/49 SYR4 2012–2019
Nitrate
2350 µg/L 24%
of the EPA limit 10000 µg/L
worst single sample: 2490 µg/L
42/42 SYR4 2012–2019
Barium
20.7 µg/L 1%
of the EPA limit 2000 µg/L
worst single sample: 25.4 µg/L
21/21 SYR4 2012–2019
Nitrate-Nitrite
1545 µg/L 15%
of the EPA limit 10000 µg/L
worst single sample: 1610 µg/L
14/14 SYR4 2013–2018
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Monochloroacetic Acid
5.755 µg/L
No EPA limit set
worst single sample: 7.15 µg/L
7/49 SYR4 2012–2019
Arsenic
1.06 µg/L 11%
of the EPA limit 10 µg/L
worst single sample: 1.1 µg/L
5/21 SYR4 2012–2019
Combined Radium (-226 And -228)
0.4987 pCi/L 10%
of the EPA limit 5 pCi/L
worst single sample: 0.5440 pCi/L
4/4 SYR4 2013–2017
Monobromoacetic Acid
0.6140 µg/L
No EPA limit set
worst single sample: 0.6200 µg/L
4/50 SYR4 2012–2019
Chromium
2.463 µg/L 2.5%
of the EPA limit 100 µg/L
worst single sample: 2.48 µg/L
3/21 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
2.812 pCi/L 19%
of the EPA limit 15 pCi/L
worst single sample: 2.96 pCi/L
3/4 SYR4 2013–2017
Lithium
114 µg/L
No EPA limit set
3/12 UCMR-5 2024
Combined Uranium
0.3948 µg/L 1.3%
of the EPA limit 30 µg/L
worst single sample: 0.4068 µg/L
2/4 SYR4 2013–2017
Antimony, Total
0.4000 µg/L 6.7%
of the EPA limit 6 µg/L
1/21 SYR4 2012–2019
Cyanide
27 µg/L 14%
of the EPA limit 200 µg/L
1/21 SYR4 2012–2019
Fluoride
101 µg/L 2.5%
of the EPA limit 4000 µg/L
1/21 SYR4 2012–2019
80 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CAVACCINI, JOSEPH D.
Phone
845-297-2744
Email
supervisor@townofwappingerny.gov

Frequently asked questions about United Wappinger Water Improvement Dist.

Is United Wappinger Water Improvement Dist. tap water safe to drink?

EPA monitoring detected 26 contaminants in United Wappinger Water Improvement Dist.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in United Wappinger Water Improvement Dist.'s water?

EPA monitoring detected Dichloroacetic Acid, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does United Wappinger Water Improvement Dist. serve?

United Wappinger Water Improvement Dist. reports serving 14,000 people in New York, per its EPA record.

Has United Wappinger Water Improvement Dist. had any water quality violations?

The EPA has 8 violations on file for United Wappinger Water Improvement Dist., of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.