← New York

Tap water quality report

Chelsea Ridge Apartments

EPA monitoring tested this supplier for 12 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

12
contaminants tested
9
detected
2,303
people served
3
health-based violations
Water source
GWP
Ownership
Private
Counties served
Dutchess

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
12
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
Other Monitoring Resolved 2003-01-01 → 2003-01-31
Other Monitoring Resolved 2003-01-01 → 2003-01-31
Other Monitoring Resolved 2000-07-01 → 2001-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2023
Bromodichloromethane
4.275 µg/L
No EPA limit set
worst single sample: 4.5 µg/L
6/6 SYR4 2012–2019
Chloroform
4.6 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
6/6 SYR4 2012–2019
Dibromochloromethane
3.35 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
6/6 SYR4 2012–2019
TTHM
13.025 µg/L 16%
of the EPA limit 80 µg/L
worst single sample: 13.6 µg/L
6/6 SYR4 2012–2019
Bromoform
0.8080 µg/L
No EPA limit set
worst single sample: 0.8100 µg/L
5/6 SYR4 2012–2019
Dichloroacetic Acid
2.44 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
5/6 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
3.16 µg/L 5.3%
of the EPA limit 60 µg/L
worst single sample: 3.3 µg/L
5/6 SYR4 2012–2019
Dibromoacetic Acid
1.5 µg/L
No EPA limit set
1/6 SYR4 2012–2019
3 contaminants tested, none detected
Monobromoacetic AcidMonochloroacetic AcidTrichloroacetic Acid

Utility contact

Contact
MCGARVEY, SHANNON
Phone
845-831-4745
Email
smcgarvey@dawnhomes.com

Frequently asked questions about Chelsea Ridge Apartments

Is Chelsea Ridge Apartments tap water safe to drink?

EPA monitoring detected 9 contaminants in Chelsea Ridge Apartments's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Chelsea Ridge Apartments's water?

EPA monitoring detected Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Chelsea Ridge Apartments serve?

Chelsea Ridge Apartments reports serving 2,303 people in New York, per its EPA record.

Has Chelsea Ridge Apartments had any water quality violations?

The EPA has 12 violations on file for Chelsea Ridge Apartments, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.