Tap water quality report

Fleetwood Manor W D

EPA monitoring tested this supplier for 12 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

12
contaminants tested
10
detected
564
people served
0
health-based violations
Water source
GWP
Ownership
Local government
Counties served
Dutchess

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
3
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2005-01-01
MR Monitoring Resolved 2005-01-01
MR Monitoring Resolved 1994-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0013 mg/L 8.7%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Bromodichloromethane
5.89 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
7/7 SYR4 2013–2019
Bromoform
1.76 µg/L
No EPA limit set
worst single sample: 2 µg/L
7/7 SYR4 2013–2019
Chloroform
6.19 µg/L
No EPA limit set
worst single sample: 6.4 µg/L
7/7 SYR4 2013–2019
Dibromoacetic Acid
1.81 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
7/7 SYR4 2013–2019
Dibromochloromethane
4.48 µg/L
No EPA limit set
worst single sample: 4.6 µg/L
7/7 SYR4 2013–2019
Dichloroacetic Acid
2.41 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
7/7 SYR4 2013–2019
TTHM
17.73 µg/L 22%
of the EPA limit 80 µg/L
worst single sample: 18.3 µg/L
7/7 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
4.853 µg/L 8.1%
of the EPA limit 60 µg/L
worst single sample: 5 µg/L
7/7 SYR4 2013–2019
Trichloroacetic Acid
1.368 µg/L
No EPA limit set
worst single sample: 1.39 µg/L
2/7 SYR4 2013–2019
2 contaminants tested, none detected
Monobromoacetic AcidMonochloroacetic Acid

Utility contact

Contact
THURSTON, RICHARD
Phone
845-297-2744
Email
rthurston@townofwappinger.us

Frequently asked questions about Fleetwood Manor W D

Is Fleetwood Manor W D tap water safe to drink?

EPA monitoring detected 10 contaminants in Fleetwood Manor W D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Fleetwood Manor W D's water?

EPA monitoring detected Lead, Bromodichloromethane, Bromoform, Chloroform, Dibromoacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Fleetwood Manor W D serve?

Fleetwood Manor W D reports serving 564 people in New York, per its EPA record.

Has Fleetwood Manor W D had any water quality violations?

The EPA has 3 violations on file for Fleetwood Manor W D, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.