← New York

Tap water quality report

Pawling Village

EPA monitoring tested this supplier for 83 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
22
detected
2,100
people served
13
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Dutchess

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

13
health-based violations
532
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-07-01 → 2022-09-30
MCL Health-based Resolved 2022-07-01 → 2022-09-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2007-01-01 → 2007-03-31
MCL Health-based Resolved 2007-01-01 → 2007-03-31
TT Health-based Archived 1998-02-01 → 1998-02-28
MCL Health-based Resolved 1996-08-01 → 1996-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
23000 µg/L 230%
of the EPA limit, in the worst sample — 10000 µg/L
74/74 SYR4 2012–2019
Combined Uranium
37.5331 µg/L 125%
of the EPA limit, in the worst sample — 30 µg/L
31/31 SYR4 2012–2019
Combined Radium (-226 And -228)
4.9 pCi/L 98%
of the EPA limit 5 pCi/L
19/34 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
28.2 pCi/L 188%
of the EPA limit, in the worst sample — 15 pCi/L
14/25 SYR4 2012–2019
Lead
0.0034 mg/L 23%
of the EPA limit 0.0150 mg/L
13/13 LCR 2022
Barium
78 µg/L 3.9%
of the EPA limit 2000 µg/L
12/12 SYR4 2013–2017
Gross Beta Particle Activity
21 pCi/L
No EPA limit set
11/13 SYR4 2012–2019
Nitrate-Nitrite
4050 µg/L 41%
of the EPA limit 10000 µg/L
9/9 SYR4 2014–2019
Bromodichloromethane
5.3 µg/L
No EPA limit set
6/6 SYR4 2012–2019
Bromoform
2.9 µg/L
No EPA limit set
6/6 SYR4 2012–2019
Copper
10 µg/L 0.8%
of the EPA limit 1300 µg/L
6/8 SYR4 2014–2017
Chloroform
5.2 µg/L
No EPA limit set
6/6 SYR4 2012–2019
Dibromochloromethane
6.6 µg/L
No EPA limit set
6/6 SYR4 2012–2019
TTHM
17.6 µg/L 22%
of the EPA limit 80 µg/L
6/6 SYR4 2012–2019
Dibromoacetic Acid
2.9 µg/L
No EPA limit set
5/6 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
7.3 µg/L 12%
of the EPA limit 60 µg/L
5/6 SYR4 2012–2019
Dichloroacetic Acid
3.4 µg/L
No EPA limit set
4/6 SYR4 2012–2019
Fluoride
310 µg/L 7.8%
of the EPA limit 4000 µg/L
3/12 SYR4 2013–2017
Trichloroacetic Acid
1.5 µg/L
No EPA limit set
3/6 SYR4 2012–2019
Toluene
23 µg/L 2.3%
of the EPA limit 1000 µg/L
2/36 SYR4 2012–2018
Antimony, Total
1.5 µg/L 25%
of the EPA limit 6 µg/L
1/12 SYR4 2013–2017
Lead
7 µg/L 47%
of the EPA limit 15 µg/L
1/8 SYR4 2014–2017
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TAYLOR, LAURI
Phone
845-855-1122
Email
Lauri.Taylor@putnamcounty.gov

Frequently asked questions about Pawling Village

Is Pawling Village tap water safe to drink?

EPA monitoring detected 22 contaminants in Pawling Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pawling Village's water?

EPA monitoring detected Nitrate, Combined Uranium, Combined Radium (-226 And -228), Gross Alpha, Excl. Radon And U, Lead, and others. The full list with the level and data source for each is above.

How many people does Pawling Village serve?

Pawling Village reports serving 2,100 people in New York, per its EPA record.

Has Pawling Village had any water quality violations?

The EPA has 532 violations on file for Pawling Village, of which 13 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.